The MEAS command starts wind measurement in single measurement mode based on the user-configurable averaging time. WMT700 does not send the data message automatically. Use the polling command to fetch the measurement data in the required format.
$aMEAS<CR><LF>
Name | Description |
---|---|
$ | Fixed text |
a | WMT700 address. If the value is 0, it refers to any WMT700 address |