When the WMT700 NMEA MWV profile is selected, you can set WMT700 to send messages based on the configured automatic message interval or poll MWV message using the NMEA Query command.
Parameter | Default value | Profile-specific allowed values | Description |
---|---|---|---|
address | N/A | String with 2 characters, for example WI |
Address for WMT700. The address must consist of 2 capital letters A … Z |
autoInt | 1 | 0.125 ... 1000 Resolution: 0.125 | Automatic message interval in seconds. Do not select a message interval that is shorter than the time it takes to send a data message. |
autoPort | 1 |
1 = COM1 port 2 = COM2 port |
Serial port to which WMT700 sends automatic data messages |
autoSend | 0 |
0 = Automatic messages disabled 20 = WMT700 NMEA MWV automatic data message |
Automatic data message number. Selects the data message format for automatic messages. |
com1_protocol | 0 1 | 11 = WMT700 NMEA MWV protocol | Profile for serial port COM1 |
com2_protocol | 0 | 11 = WMT700 NMEA MWV protocol | Profile for serial port COM2 |
com2_interf | N/A 2 |
0 = RS-485 1 = RS-422 3 = RS-232 |
Interface for serial port COM2 |
wndAvg | 1 | 0.125 … 3600 Resolution: 0.125 | Averaging time for wind measurement in seconds |
wndOrientation | 0 |
0 = Array facing up 1 = Array facing down |
Orientation of WMT700 array |
wndUnit | 0 2 |
0 = Meters per second 1 = Miles per hour 2 = Kilometers per hour 3 = Knots |
Wind speed unit |
wndVector | 0 | 0 = Scalar averaging | Wind averaging method |
To start continuous measurement, use the START command. Stop the measurement with the STOP command.
1 COM1 service port is always by default 0 -
WMT700 protocol. You can change this using serial commands if COM1 is needed for
protocol-specific communication.
2 Wind speed
unit and COM2 digital communication interface are defined in the order form. Default
setting may be any of the allowed options , and it can be verified from the unit's
configuration code.