Data messages - WMT700

WMT700 Series User Guide

Document code
M211095EN
Revision
K
Language
English
Product
WMT700
Document type
User guide

The data messages can contain measurement data calculated by WMT700 and information on the status and properties of the wind sensor.

For the automatic message mode, you must set the following parameters:

  • autoInt (defines the message send interval in seconds, 0.125 s resolution)
  • autoSend (0 = automatic message mode disabled, for available messages, see the following table.
  • autoPort (defines where the message is sent: 1 = COM1, 2 = COM2)

When the WMT700 protocol is used, you can use either one of the predefined message formats or user-configurable data message format.

The following table lists the data messages supported by WMT700. You need the data message numbers when you use the WMT700 protocol POLL command or the automatic message mode with any protocol.

Table 1. Data messages
Data message number Description
WMT700 data messages
20 WMT700 NMEA MWV profile message that reports average wind speed and direction.
21 WMT700 profile message that reports average wind speed and direction.
22 WMT700 profile message that reports wind speed in x and y components.
23 WMT700 profile message that reports wind speed and direction and self-diagnostics information.
24 WMT700 profile message that reports wind speed and direction and self-diagnostics information, and includes the checksum.
25 WMT700 profile message that reports wind measurement, sonic temperature, and status data, and includes the checksum.
27 ROSA - MES12 Standard profile message
WS425 and SDI-12 messages
15 WS425 A/B NMEA Extended profile message
16 WS425 A/B ASCII profile message
17 WS425 A/B SDI-12 profile message for M command
18 WS425 A/B SDI-12 profile message for V command
19 WS425 A/B NMEA Standard profile message
32 WS425 A/B WAT11 profile message
User-configurable data messages
1 Items defined by the user.
2
3
4

To select a data message when using polling, specify the corresponding data message identification number in the polling command.

To select a data message when using automatic messages, use the configuration parameters.