When you give the commands aC! or aM! followed by aD0!, the response is:
a<WS><WD><x><y><s><CR><LF>
Name | Description |
---|---|
a | Single-digit WMT700 address that corresponds to the first character of the address value |
<WS> |
Polar wind speed in selected units Format: +(ss)s.s |
<WD> |
Polar wind direction in degrees Format: +(dd)d.d |
<x> |
x component of wind speed in selected units Format: ±(ss)s.s |
<y> |
y component of wind speed in selected units Format: ±(ss)s.s |
<s> |
Static speed of sound in miles per hour Format: ±(ss)s.s |
<CR><LF> | Terminates the response. |
The above are measurement data fields.
Missing readings
If data is missing due to a measurement problem (for example, blocked paths between transducers), the measurement data is replaced with 999.9.
Example
Example of the command and response when data is missing:7D0! 7+999.9+999.9+999.9+999.9+999.9
<CR><LF>