In Vaisala WINDCAP Ultrasonic Wind Sensor WS425 User's Guide, this profile was called the Handar mode. |
The following table lists the configurable parameters and their allowed and default values for the WS425 A/B ASCII profile.
Parameter | Default value | Profile-specific allowed values | Description |
---|---|---|---|
autoInt | 1 |
0.125 ... 1000 Resolution: 0.125 |
Automatic message interval in seconds. Do not select a message interval that is shorter than the time it takes to send a data message. |
autoPort | 1 |
|
Serial port to which WMT700 sends automatic data messages. |
autoSend | 0 | 0 = Automatic messages disabled | Automatic data message number. Selects the data message format for automatic messages. |
com1_protocol | 0 1 | 3 = WS425 A/B ASCII | Profile for serial port COM1 |
com2_protocol | 3 | 3 = WS425 A/B ASCII | Profile for serial port COM2 |
com2_interf | N/A 2 |
|
Interface for serial port COM2 |
wndOrientation | 0 |
|
Orientation of the array of WMT700 |
wndUnit | 0 2 |
|
Wind speed unit |
wndVector | 0 | 0 = Scalar averaging | Wind averaging method |
1 The parameter
has no protocol-specific default value. It is determined separately in the
configuration code.
2 Wind speed
unit and COM2 digital communication interface are defined in the order form. Default
setting may be any of the allowed options, and it can be verified from the unit’s
configuration code.