If you have selected the WS425 A/B WAT11 profile, you can poll data with the following command:
<esc><id>
Name | Description |
---|---|
<esc> |
Escape character ASCII 27H |
<id> |
WMT700 ID, for example, A |
Response:
<stx><id><spd><dir>
Name | Description |
---|---|
<stx> |
Start of text character (1 digit) |
<id> |
WMT700 identification character, for example, A (1 digit) |
<spd> |
Wind speed (in meters per second) multiplied by 10. For example, 045 is 4.5 meters per second (3 digits). |
<dir> |
Wind direction with two octal numbers for 6-bit binary data, for example, 73 corresponds to (7×8+3)/64×360 = 332 degrees |
Missing reading
The WS425 A/B WAT11 message reports missing
data as slashes (/////
).