WS425 A/B WAT11 commands - WMT700

WMT700 Series User Guide

Document code
M211095EN
Revision
K
Language
English
Product
WMT700
Document type
User guide

If you have selected the WS425 A/B WAT11 profile, you can poll data with the following command:

<esc><id>
Name Description
<esc> Escape character ASCII 27H
<id> WMT700 ID, for example, A

Response:

<stx><id><spd><dir>
Name Description
<stx> Start of text character (1 digit)
<id> WMT700 identification character, for example, A (1 digit)
<spd> Wind speed (in meters per second) multiplied by 10. For example, 045 is 4.5 meters per second (3 digits).
<dir> Wind direction with two octal numbers for 6-bit binary data, for example, 73 corresponds to (7×8+3)/64×360 = 332 degrees

Missing reading

The WS425 A/B WAT11 message reports missing data as slashes (/////).