SDI-12 profile (v 1.3) - WMT700

WMT700 Series User Guide

Document code
M211095EN
Revision
K
Language
English
Product
WMT700
Document type
User guide

SDI-12 is a standard for interfacing data recorders with microprocessor-based sensors. The name stands for serial/digital interface at 1200 baud.

The SDI-12 Support Group is an association of companies that produce and use SDI-12 products with the purpose of reviewing requests to enhance, clarify, or modify the SDI-12 architecture and that votes on proposed changes to SDI-12.

For the complete SDI-12 standard text and information on the SDI-12 Support Group, see the SDI-12 web-site: www.sdi-12.org.

SDI-12 sub-modes A and B are not supported by WMT700.
When establishing the terminal connection to WMT700, set the following communication settings for the SDI-12 profile:
  • Bits per second: 1200
  • Data bits: 7
  • Parity: 1
  • Stop bits: 1
  • Flow Control: None

The following table lists the configurable parameters and their allowed and default values for the SDI-12 profile.

Table 1. Configurable parameters
Parameter Default value Profile-specific allowed values Description
address 1 1, 2, 3, 4, 5, 6, 7, 8, 9 Address for WMT700
autoPort 1

1 = COM1 port

2 = COM2 port

Serial port to which WMT700 sends automatic data messages
autoSend 0 0 = Automatic messages disabled Automatic data message number. Selects the data message format for automatic messages.
com1_protocol 0 1 1 = SDI-12 Profile for serial port COM1
com2_baud 1 1 = 1200

Baud rate for serial port COM2.

Changes take effect only after reset or the RESET command.

Note that low bit rate can affect measurement timing, if WMT700 cannot send the data message before new measurement starts.

com2_data 7 7 = 7 data bits

Data bits for serial port COM2.

Changes take effect only after reset or the RESET command.

com2_interf 0 2 2 = SDI-12 Interface for serial port COM2
com2_parity 1 1 = Even

Parity for serial port COM2.

Changes take effect only after reset or the RESET command.

com2_protocol 1 1 = SDI-12 Profile for serial port COM2
com2_stop 1 1 = 1 bit

Stop bits for serial port COM2.

Changes take effect only after reset or the RESET command

wndAvg 1

0.125 … 3600

Resolution: 0.125

Averaging time for wind measurement in seconds
wndOrientation 0

0 = Array facing up

1 = Array facing down

Orientation of the array of WMT700
wndUnit 0 2

0 = Meters per second

1 = Miles per hour

2 = Kilometers per hour

3 = Knots

Wind speed unit
wndVector 0 0 = Scalar averaging Wind averaging method

To start continuous measurement, use the START command. To stop measurement, use the STOP command.

1 The parameter has no protocol-specific default value. It is determined separately in the configuration code.
2 Wind speed unit and COM2 digital communication interface are defined in the order form. Default setting may be any of the allowed options, and it can be verified from the unit’s configuration code.
3 Wind speed unit and COM2 digital communication interface are defined in the order form. Default setting may be any of the allowed options, and it can be verified from the unit’s configuration code.