WS425 A/B SDI-12 message for V command - WMT700

WMT700 Series User Guide

Document code
M211095EN
Revision
K
Language
English
Product
WMT700
Document type
User guide

When you have given the commands aV! and aD0!, the response is the following:

a<watchdog><WS_unit><SDI-mode><spare><CR><LF>
Name Description
a Single-digit WMT700 address that corresponds to the first character of the address value
<watchdog> Number of times the watchdog has triggered. Ideally should be zero. Format: +(c)c
<WS_unit> Wind speed unit. The options are:
  • +0 = mph
  • +1 = kt
  • +2 = km/h
  • +3 = m/s
<SDI-mode> Current sub mode setting. The options are:
  • +0 = SDI-12 sub mode A
  • +1 = SDI-12 sub mode B
<spare> 1 digit for factory use, format: +c
<CR><LF> Terminates the response

The above are verification data fields.