Probe Description 1 Installation notes

HMP110, HMP110T, and HMP110REF

Humidity and temperature probe for measurement in demanding conditions. Robust stainless steel construction. Temperature-only version HMP110T available.

Plastic grid filter provides the fastest response time. For added protection, select the membrane filter, the PTFE filter, or the stainless steel sintered filter.

Measurement temperature range −40 … +80 °C (−40 … +176 °F).

Suitable for measurement inside chambers, incubators, fridges, and freezers.

Versatile mounting options using accessories.

Must be connected to RFL100 using a cable.

A constant output probe version HMP110REF is also available for validating installations. The constant output version does not measure – instead, it outputs unchanging humidity and temperature values.

HMP115 and HMP115T

Humidity and temperature probe for general purpose measurement. Temperature-only version HMP115T available.

Plastic grid filter provides the fastest response time. For added protection, select the membrane filter or the PTFE filter.

Measurement temperature range −40 … +60 °C (−40 … +140 °F).

Ideal choice for ambient measurement.

Can be integrated with the RFL100 housing or connected using a cable.

TMP115

Temperature probe for measurement in a wide range of conditions.

Available as 50 cm (1 ft 7.7 in) and 3 m (9.8 ft) long versions. Length includes the probe body and sensor tip.

Measurement temperature range −196 … +90 °C (−320 … +194 °F).

Operating temperature range of the probe body is −40 … +60 °C (−40 … +140 °F).

Suitable for measurement inside chambers, fridges, and freezers.

Can be integrated with the RFL100 housing or connected using a cable.

Sensor tip withstands immersion in glycol and liquid nitrogen.

Use the thermal dampener block accessory (item code 236310SP) to add thermal mass to the sensor tip.

GMP251

Carbon dioxide probe for %-level measurements. Designed for use in demanding applications such as life science incubators.

Measurement temperature range −40 … +60 °C (−40 … +140 °F).

When ordered with the RFL100 data logger, the probe is delivered with a mounting kit that includes a probe holder designed for use with GMP251 and the other supported probes. The kit also includes a magnetic holder for the Probe Splitter M8/M12 accessory.

Must be connected using the Probe Splitter M8/M12 accessory. Any one of the other supported probes can be connected at the same time in the M8 connector of the probe splitter.

Requires use of external power supply due to power consumption. Data logger batteries provide a backup in case the external power is not available.

Logged temperature data is limited to range −40 … +60 °C (−40 … +140 °F) when GMP251 is connected.

1 See probe datasheets for detailed probe specifications.