Device configuration
Height offset :0: 0.0 m
Tilt angle correction :0: OFF
Airplane filter :0: 200 m
Five sky condition layers :0: OFF
Sky condition :0: Activated
Data communication
Measurement :0: OK
Reporting destination :0: OK
Data generation :0: OK 0 files, status code 111
Data sending :0: OK 0
Maintenance
Maintenance overall :0: OK
Recent re-start occurred :0: Normal operation
Window condition :0: OK 100 %
Window blocking :0: OK
Hardware
Hardware overall :0: OK
Transmitter
TX overall :0: OK
TX electronics :0: OK
TX laser :0: OK
TX laser power :0: OK 96 %
TX laser safety :0: OK
Receiver
RX overall :0: OK
RX electronics :0: OK
RX sensitivity :0: OK
RX solar saturation :0: OK
RX voltage :0: OK
Servo drive module
Servo drive overall :0: OK
Servo drive electronics :0: OK
Servo drive control :0: OK
Servo drive ready :0: OK
Optics
Optics unit overall :0: OK
Optics unit electronics :0: OK
Optics unit tilt angle :0: OK 3.6°
Optics unit accelerometer :0: OK
Device control module
Module overall :0: OK
Module electronics :0: OK
Module temperature :0: OK 47.2 °C
Window blower
Window blower :0: ON
Window heater
Window heater :0: OFF
Internal heater
Internal heater :0: OFF
Monitoring
Background radiance :0: 3.6
Internal RH :0: 29.2 %
Internal pressure :0: 1006.7 hPa
Internal temperature :0: 25.4 °C
Laser temperature :0: 19.6 °C
Lowest cloud base height :0: 510 m
Vertical visibility :0: ///// m