Table 1. HMP4 measurement performance
Property Description/Value
Relative humidity
Measurement range 0–100 %RH, at max. +95 °C (203 °F) Td
Accuracy at +23 °C (+73.4 °F) 1 ±0.8 %RH (0–90 %RH)
Factory calibration uncertainty 2

±0.5 %RH (0–40 %RH)

±0.8 %RH (40–95 %RH)

T63 response time 15 s
Sensor options

HUMICAP® R2

HUMICAP® R2C 3

Temperature
Measurement range −70 … +180 °C (−94 … +356 °F)
Accuracy 1 4 ±0.1 °C (±0.18 °F)
Factory calibration uncertainty 2 ±0.1 °C (±0.18 °F) at +23 °C (+73.4 °F)
Sensor Pt100 RTD Class F0.1 IEC 60751
Figure 1. HMP4 humidity measurement accuracy as a function of temperature
Figure 2. HMP4 temperature measurement accuracy over full range
Table 2. HMP4 operating environment
Property Description/Value
Operating temperature of probe body −40 … +80 °C (−40 … +176 °F)
Operating temperature of probe head −70 … +180 °C (−94 … +356 °F)
Operating humidity of probe head Max. +100 °C (212 °F) Td
Storage temperature −40 … +80 °C (−40 … +176 °F)
Operational pressure < 100 bar
Operating environment Suitable for outdoor use
Measurement environment

For air, nitrogen, hydrogen, argon, helium, oxygen, and vacuum 5

IP rating of probe body

IP66: Dust-tight. Protected from powerful water jets from any direction.

Table 3. HMP4 inputs and outputs
Property Description/Value
Operating voltage 15–30 V DC
Current consumption 10 mA typical, 500 mA max.
Digital output RS-485, non-isolated
Protocols Modbus RTU
Table 4. HMP4 output parameters
Output parameter name and unit
Absolute humidity (g/m3) Relative humidity (%RH)
Absolute humidity at NTP (g/m3) Relative humidity (dew/frost) (%RH)
Dew point temperature (°C) Temperature (°C)
Dew/frost point temperature (°C) Water concentration (ppmv)
Dew/frost point temperature at 1 atm (°C) Water concentration (wet basis) (vol‑%)
Dew point temperature at 1 atm (°C) Water mass fraction (ppmw)
Dew point temperature difference (°C) Water vapor pressure (hPa)
Enthalpy (kJ/kg) Water vapor saturation pressure (hPa)
Mixing ratio (g/kg) Wet-bulb temperature (°C)
Table 5. HMP4 compliance
Property Value/Description

EU directives and regulations

EMC Directive (2014/30/EU)

RoHS Directive (2011/65/EU) amended by 2015/863

Electromagnetic compatibility (EMC)

EN 61326‑1, industrial environment

Type approvals

DNV GL certificate no. TAA00002YT

Compliance marks

CE, China RoHS, RCM

Table 6. HMP4 mechanical specifications
Property Description/Value
Connector M12 5-pin A-coded male
Fitting body M22×1.5 or NPT1/2”
Weight (with a 2-m cable) 530 g (18.7 oz)
Probe cable length 2 m (6.56 ft)
Materials
Probe AISI 316
Probe body AISI 316
Cable jacket FEP
Figure 3. HMP4 probe dimensions
1 Defined against calibration reference. Including non-linearity, hysteresis, and repeatability.
2 Defined as ±2 standard deviation limits. Small variations possible; see calibration certificate.
3 Sensor purge feature available with this sensor.
4 Exposing temperature sensor to temperatures outside −20 … +150 °C (−4 … +302 °F) may cause permanent additional deviation of ±0.1 °C (0.18 °F)
5

Consult Vaisala if other chemicals are present. Consider safety regulations with flammable gases.