Wiring WAA252 and WAV252 with WAC155 - WAC155

WAC155 User Guide

Document code
M210822EN
Revision
F
Language
English
Product
WAC155
Document type
User guide
The following wiring diagrams show how to wire the WA25 sensors with WAC155:
  • No external operating voltage
  • Low-current operating power needed
If you have WA25, you configure WAC155. See Configuring WAC155 for WA25.

No external operating voltage

The following figure shows the simplest wiring for the WA25 series wind sensors with Vaisala Mains Power Supply WHP25. WAA252 supplies WAC155 with the operating power (+12 Vout to X2/3). No external operating voltage is applied to connector X2. The expansion connector required for high-current wiring is included in the WAA252 accessories.

WHP25 is sold only as a spare part.
Figure 1. Wiring WA25 series wind sensors without external operating voltage

Low-current operating power needed

The following figure shows the WA25 wiring for applications where low-current operating power is needed also when heating power is not available. The expansion connector required for high-current wiring is included in the WAA252 accessories.

WAA252 accessories include the expansion connector required for the high current wiring.
Figure 2. Wiring for WA25 series wind sensors with low-current backup power connection