The following table describes WAC155 error codes. If you use the ERRS command to specify an error mask, use the hexadecimal values. To use the service connection to read the errors and configure WAC155, see Configuration commands.
Error number | Hex equivalent | Message | Description |
---|---|---|---|
0 | 0001 | Input voltage too low | Input voltage below accepted limit, sensor behavior not defined. |
1 | 0002 | Sensor driving voltage too high | Over-voltage condition. |
2 | 0004 | Wind speed sensor missing or broken | Self-diagnostics does not detect the proper voltage drop caused by an operational sensor. |
3 | 0008 | Wind direction sensor missing or broken | Self-diagnostics does not detect the proper voltage drop caused by an operational sensor. |
4 | 0010 | Both sensors missing or broken | Wind speed and direction sensors are missing or broken. |
5 | 0020 | Internal error | Reserved for future use. |
6 | 0040 | Erroneous reading from temperature sensor | Internal temperature sensor gives erroneous readings. |
7 | 0080 | Internal error in non-volatile memory access | Storing or reading parameters from the internal non-volatile memory has failed. |
8 | 0100 | Internal error | Reserved for future use. |
9 | 0200 | Temperature sensor not calibrated. Heating control malfunctioning. | Factory calibration has not been performed or is lost; temperature readings are erroneous. |
10 | 0400 | Wind direction sensor stuck | The wind vane has not turned for a certain period, but the anemometer has. |
11 | 0800 | Wind speed sensor stuck | Anemometer has not turned for the configured period of time, but the wind vane has. |
12 | 1000 | Both wind sensors stuck | Both wind sensors have not turned for a long time. |