The following tables list the model codes for the sanitary compact refractometer mounting hardware.

Table 1. Mounting hardware without wash nozzles

Model

Description

AFC

Elbow flow cell

Refractometer connection

‑H

Sanitary clamp, 2.5 in

Material of construction

SS

AISI 316 L

Process connection

‑H

Sanitary clamp

Pipe section diameter

  • 10
  • 15
  • 20
  • 25
  • 30
  • 40
  • 25 mm (1 in) 1
  • 40 mm (1 1/2 in)
  • 50 mm (2 in)
  • 65 mm (2.5 in) 1
  • 80 mm (3 in) 1
  • 100 mm (4 in) 1
Table 2. EHEDG certified mounting hardware

Model

Description

AFC

Elbow flow cell

Refractometer connection

‑H

Sanitary clamp, 2.5 in

Material of construction

SS

AISI 316 L

Process connection

‑H

Sanitary clamp

Pipe section diameter

20

50 mm (2 in)

Flow cell inlet type

‑SI

Straight pipe

EHEDG

‑EH

EHEDG Type EL Class I Certified Model

For EHEDG certified refractometers use ISO2852 type EHEDG certified gasket PR-9202-EH (2½ in) or PR-9272-EH (4 in).
Table 3. Mounting hardware with wash nozzles

Model

Description

AFC

Elbow flow cell

Refractometer connection

‑H

Sanitary clamp, 2.5 in

Material of construction

SS

AISI 316 L

Process connection

‑H

Sanitary clamp

Pipe section diameter

  • 10
  • 15
  • 20
  • 25
  • 30
  • 40
  • 25 mm (1 in)
  • 40 mm (1.5 in)
  • 50 mm (2 in)
  • 65 mm (2.5 in) 2
  • 80 mm (3 in) 2
  • 100 mm (4 in) 2

Flow cell inlet type

‑SI

Straight pipe

‑RI

Reduced pipe (cone)

Wash nozzle connection

‑NC

Nozzle connection

Wash nozzles for 10/15 flow cells

‑SN

Steam nozzle, G¼ thread female

‑WN

Water nozzle, G¼ thread female

‑WP

Pressurized water nozzle, G¼ thread female

‑PG

Plug for nozzle connection

Example:

  • Refractometer: PR-43-AC-73-H25-P15
  • Flow cell: AFC-HSS-H20-SI
Prism wash control and diagnostics require the use of a Multichannel user interface MI (or your own control system).
Table 4. Mounting hardware, mini flow cell

Model

Description

MFC

Mini flow cell

Refractometer connection

‑H

Sanitary clamp, 2.5 in

Material of construction

SS

AISI 316 L

Process connection

‑H

Sanitary clamp

Pipe section diameter

05

15 mm (0.5 in)

Table 5. Mounting hardware, Varinline® DN65 connection

Model

Description

TDN Varinline® in-line access unit clamp DN65 Type N 3

Pipe section diameter

  • -40
  • -50
  • -65
  • -80
  • -100
  • -125
  • -150
  • 100 mm (4 in)
  • 50 mm (2 in)
  • 65 mm (2.5 in)
  • 80 mm (3 in)
  • 100 mm (4 in)
  • 125 mm (5 in)
  • 150 mm (6 in)

Counter flange options

‑SN

Steam nozzle, G¼ thread female

‑WN

Water nozzle, G¼ thread female

‑WP

Pressurized water nozzle, G¼ thread female

‑PG

Varinline® blind flange type N
Table 6. Mounting hardware

Model

Description

SFC

Side flow cell 4
Refractometer connection
-HH

Sanitary clamp, 2.5 in

Material of construction

SS

AISI 316 L

Process connection

‑H

Sanitary clamp

Pipe section diameter

  • 10
  • 15
  • 20
  • 25
  • 25 mm (1 in)
  • 40 mm (1.5 in)
  • 50 mm (2 in)
  • 65 mm (2.5 in) 4

Flow cell inlet and outlet orientation

-090

Elbow, 90° bend

‑180

Straight pipe, 180°

1 With -SI option only
2 With -SI option only
3 Includes one 2.5 in Type N blind flange with 2.5 in EPDM gasket and 2.5 in Varinline® clamp Type N
4 Includes one 2.5 in blind flange with 2.5 in EPDM gasket and 2.5 in sanitary clamp is included