The following table lists the model codes for the sanitary probe refractometer for large pipelines and vessels.

Table 1. Sanitary probe refractometer for large pipelines and vessels

Model

Description

PR-43 Refractometer
Refractometer model
-AP Sanitary process refractometer, probe
Prism material and refractive index range limit

‑73

R.I. 1.320–1.530 nD (0 … 100 Brix) sapphire prism

Connection type and size
-E25-P15 Varinline® DN65, 15 bar
-H25-P15 Sanitary clamp, 63.5 mm (2.5 in), 15 bar
-H25-P40 Sanitary clamp, 63.5 mm (2.5 in), high pressure, 40 bar at +20 °C (+68 °F)
-H40-P15 Sanitary clamp, 101.6 mm (4 in), 15 bar
-T10-P15 MT4 DN25/1T APV tank bottom flange, flush mounted 1 in DN10
-V25-P15 63.5 mm (2.5 in), 15 bar with O-ring for refractometer head
Insertion length, models H25-P15/P40
-L14 Insertion length 14 mm (0.55 in) 1 2
-L42 Insertion length 42 mm (1.65 in) 1 2
-L140 Insertion length 140 mm (5.5 in) 3
-L170 Insertion length 170 mm (6.69 in) 1 2
Insertion length, models H40-P15
-L63 Insertion length 63 mm (2.48 in) 1 2
-L170 Insertion length 170 mm (6.69 in) 1 2
Insertion length, models T10-P15
-L100 Flush mount insertion length 2
-L170 Insertion length 170 mm (6.69 in) 3
Insertion length, models E25-P15
-L170 Insertion length 170 mm (6.69 in) 1 2
Insertion length, models V25-P15
-L170 Insertion length 170 mm (6.69 in) 3
Refractometer wetted parts material

‑SS

AISI 316 L

Electrical classification

-UN Unclassified area, general purpose, ordinary location

‑AX

ATEX and IECEx certified Ex II 3G, Ex ec IIC T4 Gc (up to zone 2), Tamb −40 … +65 °C (−40 … +149 °F)

EHEDG option

‑EH

EHEDG Type EL Class I Certified Model

4
Table 2. Sanitary probe refractometer with prism wash for large pipelines and vessels

Model

Description

PR-43 Refractometer
Refractometer model
-AP Sanitary process refractometer, probe
Prism material and refractive index range limit

‑73

R.I. 1.320–1.530 nD (0 … 100 Brix) sapphire prism

Connection type and size
-H40-P15 Sanitary clamp, 101.6 mm (4 in), 15 bar
Insertion length
-L170 Insertion length 170 mm (6.69 in)
Refractometer wetted parts material

‑SS

AISI 316 L

Electrical classification

-UN Unclassified area, general purpose, ordinary location

‑AX

ATEX and IECEx certified Ex II 3G, Ex ec IIC T4 Gc (up to zone 2), Tamb ‑40 … +65 °C (‑40 … +149 °F)
Wash nozzle connection
-NC Integral nozzle connection

‑SN

Integral steam cleaning nozzle

-WP

Integral high pressure water cleaning nozzle

‑WN

Integral warm water cleaning nozzle
-YC No integral nozzle connection
Prism wash control and diagnostics require use of Multichannel user interface MI (or your own control system).
1 EHEDG certified versions available
2 Sanitary 3-A certified
3 Design according to Sanitary 3-A
4 For models with EHEDG certified versions available