Model and description | Model |
---|---|
PR-33 = Refractometer | PR-33 |
Refractometer type | |
-AC = Compact type for pipeline installation, 3‑A certified | -AC |
Refractive Index range limits | |
-73 = R.I. 1.320-1.530 nD (0-100 Brix) Sapphire prism | -73 |
Process connection | |
-H = for Sanitary 3A-clamp, 2½ inch 1 | -H |
-E = for Varivent® in-line access unit clamp DN65 1 | -E |
Wetted parts material | |
SS = AISI 316 L | SS |
Electrical classification | |
-GP = General purpose | -GP |
Housing material | |
-RS = Stainless steel AISI 304 | -RS |
Electrical connections | |
-A = 1 x 4–20 mA, 1 x Ethernet UDP/IP, power supply +24 VDC | -A |
Sensor wetted parts surface treatment option | |
-EP = Electropolished sensor wetted parts (Ra 0.38 µm, 15 µ inch) | -EP |
Example: PR-33-AC-73-HSS-GP-RS-A-EP
Model and description | Model |
---|---|
PR-33 = Refractometer | PR-33 |
Refractometer type | |
-AC = Compact type for pipeline installation, 3‑A certified | -AC |
Refractive Index range limits | |
-73 = R.I. 1.320-1.530 nD (0-100 Brix) Sapphire prism | -73 |
Process connection | |
-H = for Sanitary 3A-clamp, 2½ inch 2 | -H |
-E = for Varivent® in-line access unit clamp DN65 | -E |
Wetted parts material | |
SS = AISI 316 L | SS |
Electrical classification | |
-GP = General purpose | -GP |
Housing material | |
-RS = Stainless steel AISI 304 | -RS |
Electrical connections | |
-A = 1 x 4–20 mA, 1 x Ethernet UDP/IP, power supply +24 VDC | -A |
EHEDG | |
-EH = EHEDG Type EL Class I Certified model | -EH |
Sensor wetted parts surface treatment option | |
-EP = Electropolished sensor wetted parts (Ra 0.38 µm, 15 µ inch) | -EP |
Example: PR-33-AC-73-HSS-GP-RS-A-EH
Model and description | Model |
---|---|
AFC = Elbow flow cell | AFC |
Sensor connection | |
-H = Sanitary 3A‑clamp, 2½ inch | -H |
Material of construction | |
SS = AISI 316 L | SS |
Process connection | |
-H = Sanitary 3A clamp | -H |
Pipe section diameter | |
10 = 25 mm (1 inch) | 10 |
15 = 40 mm (1½ inch) | 15 |
20 = 50 mm (2 inch) | 20 |
25 = 65 mm (2½ inch) 3 | 25 |
Flow cell inlet type | |
-SI = Straight pipe | -SI |
-RI = Reduced pipe (cone) | -RI |
Model and description | Model |
---|---|
AFC = Elbow flow cell | AFC |
Sensor connection | |
-H = Sanitary 3A-clamp, 2½ inch | -H |
Material of construction | |
SS = AISI 316 L | SS |
Process connection | |
-H = Sanitary 3A clamp | -H |
Pipe section diameter | |
20 = 50 mm (2 inch) | 20 |
Flow cell inlet type | |
-SI = Straight pipe | -SI |
EHEDG | |
-EH = EHEDG Type EL Class I Certified Model | |
Polishing option | |
-EP = Electropolished process wetted parts (Ra 0.38 µm, 15 µ inch) | -EP |
Model and description | Model |
---|---|
MFC = Mini Flow Cell | MFC |
Sensor connection | |
-H = Sanitary 3A-clamp, 2½ inch | -H |
Material of construction | |
SS = AISI 316 L | SS |
Process connection | |
-H = Sanitary 3A clamp | -H |
Pipe section diameter | |
05 = 15 mm (½ inch) | 05 |
1 Sensor only without
clamp, gasket and ferrule.
2 Complete with clamp,
gasket and ferrule.
3 With -SI option
only.