PR-33-AC model code - PR-33 - PR-33-AC

PR-33-AC User Guide

Document code
M212411EN
Revision
B
Language
English
Product
PR-33
PR-33-AC
Document type
User guide
Table 1. SANITARY OEM REFRACTOMETER for pipelines (3-A Sanitary Standard 46-04 Certified)
Model and description Model
PR-33 = Refractometer PR-33
Refractometer type
-AC = Compact type for pipeline installation, 3‑A certified -AC
Refractive Index range limits
-73 = R.I. 1.320-1.530 nD (0-100 Brix) Sapphire prism -73
Process connection
-H = for Sanitary 3A-clamp, 2½ inch 1 -H
-E = for Varivent® in-line access unit clamp DN65 1 -E
Wetted parts material
SS = AISI 316 L SS
Electrical classification
-GP = General purpose -GP
Housing material
-RS = Stainless steel AISI 304 -RS
Electrical connections
-A = 1 x 4–20 mA, 1 x Ethernet UDP/IP, power supply +24 VDC -A
Sensor wetted parts surface treatment option
-EP = Electropolished sensor wetted parts (Ra 0.38 µm, 15 µ inch) -EP

Example: PR-33-AC-73-HSS-GP-RS-A-EP

Table 2. SANITARY OEM REFRACTOMETER for pipelines (3-A Sanitary Certified and EHEDG certified)
Model and description Model
PR-33 = Refractometer PR-33
Refractometer type
-AC = Compact type for pipeline installation, 3‑A certified -AC
Refractive Index range limits
-73 = R.I. 1.320-1.530 nD (0-100 Brix) Sapphire prism -73
Process connection
-H = for Sanitary 3A-clamp, 2½ inch 2 -H
-E = for Varivent® in-line access unit clamp DN65 -E
Wetted parts material
SS = AISI 316 L SS
Electrical classification
-GP = General purpose -GP
Housing material
-RS = Stainless steel AISI 304 -RS
Electrical connections
-A = 1 x 4–20 mA, 1 x Ethernet UDP/IP, power supply +24 VDC -A
EHEDG
-EH = EHEDG Type EL Class I Certified model -EH
Sensor wetted parts surface treatment option
-EP = Electropolished sensor wetted parts (Ra 0.38 µm, 15 µ inch) -EP

Example: PR-33-AC-73-HSS-GP-RS-A-EH

Table 3. Elbow Flow Cells for PR-33-AC
Model and description Model
AFC = Elbow flow cell AFC
Sensor connection
-H = Sanitary 3A‑clamp, 2½ inch -H
Material of construction
SS = AISI 316 L SS
Process connection
-H = Sanitary 3A clamp -H
Pipe section diameter
10 = 25 mm (1 inch) 10
15 = 40 mm (1½ inch) 15
20 = 50 mm (2 inch) 20
25 = 65 mm (2½ inch) 3 25
Flow cell inlet type
-SI = Straight pipe -SI
-RI = Reduced pipe (cone) -RI
Table 4. EHEDG Certified Elbow Flow Cells, connection Sanitary 3A-clamp 2½ inch
Model and description Model
AFC = Elbow flow cell AFC
Sensor connection
-H = Sanitary 3A-clamp, 2½ inch -H
Material of construction
SS = AISI 316 L SS
Process connection
-H = Sanitary 3A clamp -H
Pipe section diameter
20 = 50 mm (2 inch) 20
Flow cell inlet type
-SI = Straight pipe -SI
EHEDG
-EH = EHEDG Type EL Class I Certified Model
Polishing option
-EP = Electropolished process wetted parts (Ra 0.38 µm, 15 µ inch) -EP
Table 5. Mounting hardware for PR-33-AC
Model and description Model
MFC = Mini Flow Cell MFC
Sensor connection
-H = Sanitary 3A-clamp, 2½ inch -H
Material of construction
SS = AISI 316 L SS
Process connection
-H = Sanitary 3A clamp -H
Pipe section diameter
05 = 15 mm (½ inch) 05
1 Sensor only without clamp, gasket and ferrule.
2 Complete with clamp, gasket and ferrule.
3 With -SI option only.