BACnet Protocol Implementation Conformance Statement - HMD60 - HMD65

HMD65 User Guide

Document code
M212243EN
Revision
C
Language
English
Product
HMD60
HMD65
Document type
User guide

This statement is a part of the BACnet standard and is required for its use.

Vendor name: Vaisala Oyj
Product Name: HMD60 Series
Product Model Numbers: HMD60, HMD65
Application Software Version: 2.0.8 (or greater)
Firmware Version: 2 (Interface version)
BACnet Protocol Revision: Version 1, Revision 15
BACnet Standardized Device Profile (Annex L):

BACnet Operator Workstation (B-OWS)

BACnet Building Controller (B-BC)

BACnet Advanced Application Controller (B-AAC)

BACnet Application Specific Controller (B-ASC)

BACnet Smart Sensor (B-SS)

BACnet Smart Actuator (B-SA)

List of all BACnet Interoperability Building Blocks Supported (Annex K):

See also: BIBBs Supported

DS-RP-B, DS-RPM-B, DS-WP-B, DS-COVU-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-RD-B
Segmentation Capability:

Segmentation Requests Supported

Segmentation Responses Supported

No segmentation.

Standard Object Types Supported

Analog Input

Analog Output

Analog Value

Averaging

Binary Input

Binary Output

Binary Value

Calendar

Command

Device

Event Enrollment

File

Group

Life Safety Point

Life Safety Zone

Loop

Multistate Input

Multistate Output

Multistate Value

Notification Class

Program

Schedule

Trend Log

Data Link Layer Options

BACnet Internet Protocol (IP) (Annex J)

BACnet IP (Annex J), Foreign Device

ISO 88023, Ethernet (Clause 7)

ANSI/ATA 878.1, 2.5 MB ARCNET® network (Clause 8)

ANSI/ATA 878.1, RS485 ARCNET network (Clause 8), baud rates: _________

Master-Slave/Token-Passing (MS/TP) master (Clause 9), baud rates: 9600, 19200, 38400, 57600, 76800, 115200

MS/TP slave (Clause 9), baud rates: _________

Point-To-Point, EIA 232 (Clause 10), baud rates: _________

Point-To-Point, modem (Clause 10), baud rates: _________

LonTalk® protocol (Clause 11), medium: _________

Other: _________

Device Address Binding:

Is static device binding supported? (required for two-way communication between MS/TP slaves and other devices)

Yes

No

Networking Options

Router, Clause 6: _________

Annex H, BACnet Tunneling Router over IP

BACnet/IP Broadcast Management Device (BBMD)

Does the BBMD support registrations by Foreign Devices?

Yes

No

Character Sets Supported:

Indicating support for multiple character sets does not imply that they can all be supported simultaneously.

UTF-8 / ANSI X3.4

IBM®/Microsoft® DoubleByte Character Set (DBCS)

ISO 8859-1

ISO 10646 Universal Character Set-2 (UCS2)

ISO 10646 (UCS-4)

Japanese Industrial Standard (JIS) C 6226

Types of non-BACnet equipment /network(s) supported: None