HMD65 Basic Features and Options - HMD60 - HMD65

HMD65 User Guide

Document code
M212243EN
Revision
C
Language
English
Product
HMD60
HMD65
Document type
User guide
  • Humidity and temperature measurement:
    • available humidity parameters: RH, Td, Tdf, A, X, Tw, H
    • T measurement in °C or °F
  • Analog output: 2 analog 0 … 10 V output channels for humidity and temperature measurements
  • Digital output (RS-485): Modbus RTU and BACnet MS/TP
  • Power supply input: 15 … 35 VDC / 16 … 24 VAC
  • Configuration and adjustment options:
    • RH and T measurement field adjustment with trimmers
    • Humidity output parameter selection and Modbus/BACnet serial setting configuration with DIP switches
    • Configuration and adjustment with Vaisala Insight PC software
    • Configuration with Modbus and BACnet
    • Field adjustment with MI70 handheld indicator