Mounting WXT530 on pole mast - BWS500

BWS500 Setup Guide

Document code
M212787EN
Revision
E
Language
English
Product
BWS500
Document type
User guide

Mount WXT530 series transmitter on top of the pole mast. If you mount the transmitter on a Ø 60 mm (2.36 in) pole mast, use an additional mounting adapter.

Keep the upper part of the protective cushion on during the installation.
  1. Lead the sensor cable through the mounting kit, and for 60‑mm (2.36 in) masts, also through the mounting adapter.
  2. Connect and tighten the cable.
  3. Insert the mounting kit adapter and turn it firmly until you feel the adapter snap into the locked position.
  4. Run the sensor cable through the mounting adapter. Attach the sensor to the mounting adapter or mast. Tighten the mounting adapter with wrench.
  5. Align the sensor so that the arrow points to north.
  6. Tighten the fixing screw to keep the sensor firmly in place. Remove the protective cushion.