Introduction to Vaisala Radiosonde RS41 - RS41-SGM

RS41-SGM User Guide

Document code
M211752EN
Revision
F
Language
English
Product
RS41-SGM
Document type
User guide

Vaisala Radiosonde RS41 offers excellent data availability and accuracy of humidity, temperature, pressure, and wind measurement. The radiosonde is fast and stable with individual, SI-standard traceable calibration.

Vaisala Radiosonde RS41 temperature sensor uses linear resistive platinum technology. The small size of the sensor results in low solar radiation error and guarantees fast response. Wind data, height and pressure are derived from Vaisala Radiosonde RS41 GPS data combined with differential corrected GPS data from the ground station.

Robust design, physical zero humidity check and in-built functional temperature check ensure reliable performance in every situation. The radiosonde is also easy to use. For example, there is no need for the user to connect the batteries to the radiosonde to activate it. The radiosonde is automatically activated when placed on the ground check device. To make it easier to check the status of the radiosonde, the radiosonde has LED light indicators visible on the cover.

Radiosonde RS41-SGM features radio silence, which means that the radiosonde can be launched in radio silence up to a specified height. All data is recorded also during the radio silence and, when the radio silence ends, transmitted to the ground equipment. All transmitted data is encrypted, and surface observations can be obtained directly from the radiosonde.

Figure 1. Vaisala Radiosonde RS41 with unwinder
1
Sensor boom
2
Power switch
3
Additional sensor interface connector
4
Antenna
5
LED light
6
Unwinder
7
Unwinder stick
Table 1. Operating environment
Property Description / Value
Function Radiosonde for atmospheric measurement, outdoor use

Maximum operating altitude

> 5000 m (16 404 ft), from ground level up to 40 km (131 234 ft)

Operating temperature

−90 … +60 °C (−130 …+140 °F)

Operating humidity

0 … 100 %RH

Power source Battery powered, no mains power
Overvoltage category CAT I

Use in wet location

Yes

Pollution degree

3