Connections - WAT12

WAT12 User Guide

Document code
M210309EN
Revision
B
Language
English
Product
WAT12
Document type
User guide

WAT12 provides the line cable entry through a gland for a cable with a diameter 7 ... 10 mm. For better protection against RF interference, bend the cable shield.

Figure 1. Cable shield bent over plastic sleeve and o-ring

WAT12 has 3 I/O connectors

1
X1: For the anemometer cable
2
X2: For the power and signal cable
3
X3: For the wind vane cable
Table 1. I/O connectors
Connector Description
X1 Plug-in connector with screw terminals (5 pcs) for the anemometer cable. Maximum wire cross section area is 1.5 mm2.
X2 Plug-in connector with screw terminals (8 pcs) for the power and signal cable. Maximum wire cross section area is 1.5 mm2.
X3 Plug-in connector with screw terminals (11 pcs) for the wind vane cable. Maximum wire cross section area is 1.5 mm2.