Connecting FD70 and LM21 cables to host system - LM21 - FD70

Installing Background Luminance Sensor LM21 to FD70 without Interface Unit Technical Note

Product status
Document code
M213409EN-A
ft:locale
en-US
Product
LM21
FD70
Document type
Technical note
Connect the FD70 cable (FD70CABLE) and the LM21 connection cable (CBL210820) as shown in the following figure. Terminate the wires to a terminal strip inside a separate connection box (not included in the upgrade kit) or directly on the terminal strip of the host system.
FD70 cable (FD70CABLE) connections
FD70 (FD70CABLE) Wire size (mm2) Wire color Description
7 1 Black Operating voltage Vin−
6 1 Red Operating voltage Vin+
5 1 White-red Heating voltage VH+
8 1 White-black Heating voltage VH−
13 0.14 Violet COM3: RS-485A−
2 0.14 White-violet COM3: RS-485B+
1 0.25 Brown Day/Night switch
14 0.14 White-orange Ethernet TX+
4 0.14 Orange Ethernet TX−
15 0.14 White-green Ethernet RX+
3 0.14 Green Ethernet RX−
10 0.14 White-blue COM1: GND1
16 0.14 Pink COM1: RS-232 TX / RS-485B
9 0.14 White-pink COM1: RS-232 RX / RS-485A
11 0.25 Blue COM2: GND2
12 0.14 Gray COM2: RS-232 TX / RS-485B
17 0.14 White-gray COM2: RS-232 RX / RS-485A
FD70CABLE is available in several lengths.
LM21 cable (CBL210820) connections
LM21 (CBL210820) Wire size (mm2) Wire color Description
5 0.34 Gray GND
6 0.34 Pink Operating voltage Vin+
1 and 7 2 x 0.34 White and blue Heating voltage VH+
2 and 8 2 x 0.34 Brown and red Heating voltage VH−
4 0.34 Yellow COM3: RS-485A−
3 0.34 Green COM3: RS-485B+