Connect the FD70 cable (FD70CABLE) and the LM21 connection cable (CBL210820) as shown
in the following figure. Terminate the wires to a terminal strip inside a separate
connection box (not included in the upgrade kit) or directly on the terminal strip of the
host system.
| FD70 (FD70CABLE) | Wire size (mm2) | Wire color | Description |
|---|---|---|---|
| 7 | 1 | Black | Operating voltage Vin− |
| 6 | 1 | Red | Operating voltage Vin+ |
| 5 | 1 | White-red | Heating voltage VH+ |
| 8 | 1 | White-black | Heating voltage VH− |
| 13 | 0.14 | Violet | COM3: RS-485A− |
| 2 | 0.14 | White-violet | COM3: RS-485B+ |
| 1 | 0.25 | Brown | Day/Night switch |
| 14 | 0.14 | White-orange | Ethernet TX+ |
| 4 | 0.14 | Orange | Ethernet TX− |
| 15 | 0.14 | White-green | Ethernet RX+ |
| 3 | 0.14 | Green | Ethernet RX− |
| 10 | 0.14 | White-blue | COM1: GND1 |
| 16 | 0.14 | Pink | COM1: RS-232 TX / RS-485B |
| 9 | 0.14 | White-pink | COM1: RS-232 RX / RS-485A |
| 11 | 0.25 | Blue | COM2: GND2 |
| 12 | 0.14 | Gray | COM2: RS-232 TX / RS-485B |
| 17 | 0.14 | White-gray | COM2: RS-232 RX / RS-485A |
| FD70CABLE is available in several lengths. |
| LM21 (CBL210820) | Wire size (mm2) | Wire color | Description |
|---|---|---|---|
| 5 | 0.34 | Gray | GND |
| 6 | 0.34 | Pink | Operating voltage Vin+ |
| 1 and 7 | 2 x 0.34 | White and blue | Heating voltage VH+ |
| 2 and 8 | 2 x 0.34 | Brown and red | Heating voltage VH− |
| 4 | 0.34 | Yellow | COM3: RS-485A− |
| 3 | 0.34 | Green | COM3: RS-485B+ |