Installing Background Luminance Sensor LM21 to FD70 without interface unit - LM21 - FD70

Installing Background Luminance Sensor LM21 to FD70 without Interface Unit Technical Note

Product status
Document code
M213409EN-A
ft:locale
en-US
Product
LM21
FD70
Document type
Technical note

This document describes how to install the background luminance sensor LM21 on FD70 without an interface unit using the upgrade kit LM21UPGFD70WS.

WARNING Only licensed experts may install electrical components. Ensure that mains-connected equipment, power supplies, and installation accessories adhere to local and state legislation and regulations.
WARNING Make sure that you prepare or connect only de-energized wires.

LM21UPGFD70WS upgrade kit

The kit consists of:

  • Background luminance sensor LM21
  • Connection cable LM21-FD70 (CBL210820)
  • Mounting bracket (DRW234470)
  • This technical note (M213409EN)

You need a separate connection box for connecting LM21 and FD70 wires. It is not included in the upgrade kit.

LM21 mounting requirements

LM21 mounting requirements
Property Description
Orientation
  • Avoid direct and reflected sunlight into the sensor.
  • Avoid pointing LM21 directly at runway lights.
Tilt angle
  • 20–50° from horizontal level
  • Aim the sensor so that it points just above the runway lights.

    You can orient the sensor at a smaller vertical angle, as long as you make sure it observes only the sky. Keep the 6° field of view free of runway lights, other light sources, structures, and the ground.

If you need to fine-tune the viewing direction of LM21, turn the mounting bracket. Tighten the screws after the adjustment.