Wiring WMT700 integrated cable (ASM215829) - WMT700

Wiring WMT700 Integrated Cable (ASM215829) Technical Note

Product status
Document code
M213342EN-A
ft:locale
en-US
Product
WMT700
Document type
Technical note

This document describes how to wire your WMT700 equipped with an integrated cable (ASM215829). The unit delivered to you is a standard WMT700 equipped with an integrated hybrid cable. The cable is factory-mounted to the sensor body.

WMT700 integrated cable
WARNING Make sure that you prepare only de-energized wires.
CAUTION Do not try to open or modify the bottom connector of WMT700. The connector is not detachable and opening it may damage the sensor.

For more information about WMT700 cables, see WMT700 User Guide (M211095EN) in docs.vaisala.com.

Connect the wires of the cable according to the following table.
Hybrid cable wiring
Pin Description Hybrid cable
Fully heated WMT700
1 Operating power supply Brown 0.25 mm2
11 Operating power supply ground Blue 0.25 mm2
5 Heater power supply White/red 1.0 mm2
6 Red 1.0 mm2
7 Heater power supply ground Black 1.0 mm2
8 White/black 1.0 mm2
Shield Enclosure ground
Analog outputs
2 Analog output AOUT2, wind direction White/violet 0.14 mm2
13 Analog output AOUT1, wind speed Violet 0.14 mm2
17 Reference input for AOUT2 (simulated potentiometer) White/gray 0.14 mm2
12 Analog output ground Gray 0.14 mm2
COM port RS-232 RS-422 RS-485 SDI-12
3 COM2 RS232Rx RX- RX- - Green 0.14 mm2
4 RS232Tx TX- TX- Data Orange 0.14 mm2
14 - TX+ TX+ - White/orange 0.14 mm2
15 - RX+ RX+ - White/green 0.14 mm2
10 COM1 and COM2 communication ports ground White/blue 0.14 mm2
9 COM1 service port RS-485 – White/pink 0.14 mm2
16 RS-485 + Pink 0.14 mm2