  1. Perform a final visual check inside the radiosonde compartment of the flight box to make sure that the ozone sensor tubing is firmly in place and no wires or cables are interfering with the piston pump of the ozone sensor.
  2. Position the lid of the flight box and attach by wrapping tape all the way around the outside edges of the ozone sensor to hold the lid and radiosonde support firmly in place.
  3. Depending on which sensor you use, follow instructions in step a. or b.
    1. If you use an (SPC) sensor, close the cover of the flight box and tape the seam between the cover and the body of the box.

      Do not tape the hanging strings.

      Do not tape over the air outlet and air intake tube, as the measuring gas must be able to move in and out of the sensor box.
      Air outlet hole and air intake tube not taped over
    2. If you use an (EN-SCI) sensor, attach the flight box string with another string in 2 places, indicated with the arrows in the following figure, so that the string does not hit the radiosonde sensor boom during the flight.
    Supported flight box string in EN-SCI ozone sensor flight box