Known issues - BWS500

EGW501 2.8.1 (Beam Weather Station) Release Notes

Product status
Document code
M213121EN-A
ft:locale
en-US
Product
BWS500
Document type
Release notes
Known issues
Issue Remedy
If you switch off power within 5 minutes after updating the DMU801 firmware, it may become impossible to update the firmware again. There is no workaround for this. Do not switch off power until at least 5 minutes have passed after updating the firmware.
In the Web UI and MQTT (Device Status:INPUT_POWER), power measurement does not show actual values. If you need to know the power consumption, use PSU501 measurements (PSU OUTPUT CURRENT and PSU OUTPUT VOLTAGE) in the Web UI to calculate it.

Some sensors may not work. They give a Modbus error at startup, and afterward continuously the following error:

AttributeError: 'GenericModbusClient' object has no attribute 'REG_COMP_ACT'

Restart the configuration script through the Web UI.