AWS810 Solar Edition measurements - Xweather Protect, Xweather Optimize, Xweather Observe

Xweather Protect, Xweather Optimize, Xweather Observe Measurement Parameters and Calculations

Product status
Document code
M213086EN-E
ft:locale
en-US
Product
Xweather Protect, Xweather Optimize, Xweather Observe
Document type
User guide

The following tables explain the measurements available in Vaisala cloud from AWS810 Solar Edition.

Pyranometer measurements (MS-80S, MS-80SH, SMP10, SMP12, SPN1, SR30)
Measurement Parameter name Measurement name Unit Update interval Reported value Sampling Sensor
Global horizontal irradiance (GHI) 1 GLOBAL_HORIZONTAL_IRRADIATION GHI W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH,SMP10, SMP12, SR30, SPN1
Global horizontal irradiance (GHI) 2 GLOBAL_HORIZONTAL_IRRADIATION GHI W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30, SPN1
Reflected global horizontal irradiance (GHI_R) REFLECTED_HORIZONTAL_IRRADIATION GHI_R W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30, SPN1
Horizontal albedo (ρH) ALBEDO ALBEDO 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30
Plane of array (POA) 1 1 PLANE_OF_ARRAY_IRRADIATION POAI W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30
Plane of array (POA) 2 1 PLANE_OF_ARRAY_IRRADIATION POAI W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30
Rear-side plane of array (POA) 1 2 REAR_PLANE_OF_ARRAY_IRRADIATION RPOAI W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30
Rear-side plane of array (POA) 2 2 REAR_PLANE_OF_ARRAY_IRRADIATION RPOAI W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30
Rear-side plane of array (POA) 3 2 REAR_PLANE_OF_ARRAY_IRRADIATION RPOAI W/m2 1 minute 1-minute average Every 1 second MS‑80S, MS-80SH, SMP10, SMP12, SR30
Diffuse horizontal irradiance (DHI) (Gd) DIFFUSE_HORIZONTAL_IRRADIATION DFI W/m2 1 minute 1-minute average Every 1 second SPN1
Tilt angle measurements (MS-80S, MS-80SH, SR30)
Measurement Parameter name Measurement name Unit Update interval Reported value Sampling Sensor
Tilt angle in x axis TILT_ANGLE_X TILT_X ° 1 minute 1-second instant Every 1 second MS‑80S, MS-80SH
Tilt angle in y axis TILT_ANGLE_Y TILT_Y ° 1 minute 1-second instant Every 1 second MS‑80S, MS-80SH
Tilt angle TILT_ANGLE TILT_XY ° 1 minute 1-second instant Every 1 second SR30
Reference solar cell measurements
Measurement Parameter name Measurement name Unit Update interval Reported value Sampling
Photovoltaic (PV) reference radiation PV_REFERENCE_IRRADIATION PV_SR_REF W/m2 1 minute 1-minute average Every 1 second
WXT530 series sensor measurements
Measurement Parameter name Measurement name Unit Update interval Reported value Sampling
Wind direction WIND_DIRECTION WD ° 1 minute 1‑minute average In resolution of 250 ms samples
Wind direction, min. WIND_DIRECTION WD ° 1 minute 1‑minute minimum In resolution of 250 ms samples
Wind direction, max. WIND_DIRECTION WD ° 1 minute 1‑minute maximum In resolution of 250 ms samples
Wind speed WIND_SPEED WS m/s 1 minute 1‑minute average In resolution of 250 ms samples
Wind speed, min. WIND_SPEED WS m/s 1 minute 1‑minute minimum In resolution of 250 ms samples
Wind speed, max. (gust) WIND_SPEED WS m/s 1 minute 1-minute maximum 12 samples in resolution of 250 ms
Wind gust direction WIND_GUST_DIRECTION WGD ° 1 minute 1‑minute average 12 samples in resolution of 250 ms
Air pressure AIR_PRESSURE PA hPa 1 minute 1‑minute average Every 1 second
Ambient air temperature (Tamb) AIR_TEMPERATURE TA °C 1 minute 1-minute average Every 1 second
Relative humidity RELATIVE_HUMIDITY RH %RH 1 minute 1-minute average Every 1 second
Dew point temperature DEW_POINT_TEMPERATURE DP °C 1 minute 1-minute average Every 1 second
Precipitation intensity PRECIPITATION_INTENSITY PRF mm/h 1 minute Instant Every 1 second
Precipitation accumulation PRECIPITATION_ACCUMULATION PR mm 1 minute 24-hour sum since UTC ±00:00 Every 1 second
RG13H measurements
Measurement Parameter name Measurement name Unit Update interval Reported value Sampling
Precipitation accumulation PRECIPITATION_ACCUMULATION PR mm 1 minute 24-hour sum since UTC ±00:00 Every 1 second
PT1000 measurements
Measurement Parameter name Measurement name Unit Update interval Reported value Sampling
Photovoltaic (PV) panel temperature (Tmod) 1 PV_PANEL_TEMPERATURE PVT °C 1 minute 1-minute average Every 10 seconds
Photovoltaic (PV) panel temperature (Tmod) 2 PV_PANEL_TEMPERATURE PVT °C 1 minute 1-minute average Every 10 seconds
Photovoltaic (PV) panel temperature (Tmod) 3 PV_PANEL_TEMPERATURE PVT °C 1 minute 1-minute average Every 10 seconds
DustIQ measurements
Measurement Parameter name Measurement name Unit Update interval Reported value Sampling
Photovoltaic panel temperature PV_PANEL_TEMPERATURE BP_TEMP °C 1 minute Instant Every 10 seconds
Photovoltaic panel soiling ratio (SR) 1 PV_PANEL_SOILING_RATIO SRS1 % 1 minute Instant Every 10 seconds
Photovoltaic panel soiling ratio (SR) 2 PV_PANEL_SOILING_RATIO SRS2 % 1 minute Instant Every 10 seconds
Photovoltaic panel transmission loss 1 PV_PANEL_TRANSMISSION_LOSS TR_LOSS1 % 1 minute Instant Every 10 seconds
Photovoltaic panel transmission loss 2 PV_PANEL_TRANSMISSION_LOSS TR_LOSS2 % 1 minute Instant Every 10 seconds
1 In-plane irradiance (Gi)
2 In-plane rear-side irradiance or spectrally matched in-plane rear-side irradiance (Gi / Gi, sp rear).