Configuring ASCII settings - WM80

WM80 User Guide

Document code
M212995EN
Revision
A
ft:locale
en-US
Product
WM80
Document type
User guide
  1. Create a connection to the device with Insight PC software.
  2. Select the settings icon ( ) and Configure device.
  3. Select Communication and configure the following settings.
    Bit rate
    Select the bit rate.
    Parity, data, stop bits
    Select the parity, data, and stop bits.
    Interface mode
    Select ASCII/NMEA.
  4. Select ASCII/NMEA from the left and configure the following setting.
    NMEA talker ID
    Leave as is.
    Wind speed unit
    Select m/s or kn.
    Autosend format
    Select one of the ASCII data message formats.
    Autosend interval
    Message sending interval for the selected autosend format.
  5. Select Save.