WM80 specifications - WM80

WM80 Setup Guide

Product status
Document code
M212994EN
Revision
D
ft:locale
en-US
Product
WM80
Document type
User guide
Wind measurement performance
Property Description/Value
Measurement rate 10 Hz
Averaging Up to 3600 s
Wind speed
Measurement range 0–90 m/s (0–200 mph)
Accuracy

0.1 m/s or 2 % at 0–50 m/s (0–112 mph)

5 % at > 50–90 m/s (112–200 mph)

Resolution 0.01 m/s (0.0223 mph)
Wind direction
Measurement range 0–360°
Accuracy

4° at 1–5 m/s (2–11 mph)

2° at 5–50 m/s (11–112 mph)

5° at > 50 m/s (112 mph)

Resolution 0.01°, 0.1°, or 1° (depending on the protocol)
Operating environment
Property Description/Value

Operating environment

Outdoor use

Use in wet location

Yes

Operating temperature

−40 … +60 °C (−40 … +140 °F)

Solar radiation 1120 W/m2 at +60 °C (+140 °F)

Operating humidity

0–100 %RH, condensing
Survival wind speed

100 m/s (224 mph)

Maximum operating altitude

4000 m (approx. 13 100 ft)

Pollution degree

4

IP rating

IP66: Dust-tight. Protected from powerful water jets from any direction.

IP67: Dust-tight. Protected from the effects of temporary immersion in water under standardized conditions of pressure and time.

UL 50E/NEMA rating

Type 4: Dust-tight. Protected from hose-directed water.

Storage temperature

−40 … +85 °C (−40 … +185 °F)

Storage humidity

0–100 %RH, non‑condensing

Heater control Automatic