The interface is described in its full static extent as a traditional Modbus map.

When used as a dynamic SunSpec Modbus interface, different models, as identified by their SunSpec model identifiers, are present or missing depending on the configuration of the system. The only fixed block is the common model contained in addresses 1 through 69.

The default TCP port for the interface is 5020.

For SunSpec Modbus specifications, see sunspec.org/sunspec-modbus/.

Table 1. Table reading instructions
Value Description
Address Modbus register address
Length Number of Modbus registers for the data
Description Content of the register. Registers that contain measurements provide 1‑minute averages.
Datatype Data type for the content
Unit Unit of measure
Factor

Power of ten to multiply the value with to scale a measurement.

For example, factor −1 applied to register value 123 gives 12.3 as the measurement value.

Fixed value Fixed register value, if any. If fixed value is the same as error value, it indicates that the measurement is unavailable in the product.
Error value Value for an unavailable measurement, either due to a measurement failure or the measurement not being present in the setup.
Table 2. AWS810 Solar Edition Modbus register map
Address Length Description Datatype Unit Factor Fixed Value Error Value
0 2 SunSpec Modbus map identifier string n/a n/a SunS Empty
2 1 SunSpec common model identifier uint16 n/a n/a 1 Empty
3 1 Common model length uint16 n/a n/a 65 Empty
4 16 Manufacturer string n/a n/a Vaisala Empty
20 16 Model string n/a n/a AWS810 Solar Edition Empty
36 8 Options string n/a n/a Empty Empty
44 8 Firmware version string n/a n/a Empty Empty
52 16 Serial number string n/a n/a Empty Empty
68 1 Modbus address uint16 n/a n/a 0 Empty
69 1 Even padding int16 n/a n/a Empty Empty
70 1 Sunspec base met model identifier uint16 n/a n/a 307 Empty
71 1 Base met model length uint16 n/a n/a 11 Empty
72 1 Ambient temperature int16 °C −1 Empty −32768
73 1 Relative humidity int16 % 0 Empty −32768
74 1 Barometric pressure int16 hPa 0 Empty −32768
75 1 Wind speed int16 m/s 0 Empty −32768
76 1 Wind direction int16 deg 0 Empty −32768
77 1 Rainfall int16 mm 0 Empty −32768
78 1 Precipitation type int16 WMO4680 0 −32768 −32768
79 1 Electric field int16 Vm 0 −32768 −32768
80 1 Surface wetness int16 kO 0 −32768 −32768
81 1 Soil wetness int16 % 0 −32768 −32768
82 1 Sunspec irradiance model identifier uint16 n/a n/a 302 Empty
83 1 Irradiance model length uint16 n/a n/a 15 Empty
84 1 Global horizontal irradiance #1 uint16 W/m² 0 Empty 65535
85 1 Plane of array irradiance #1 uint16 W/m² 0 Empty 65535
86 1 Diffuse irradiance #1 uint16 W/m² 0 65535 65535
87 1 Direct irradiance #1 uint16 W/m² 0 65535 65535
88 1 Rear side plane of array irradiance #1 uint16 W/m² 0 Empty 65535
89 1 Global horizontal irradiance #2 uint16 W/m² 0 Empty 65535
90 1 Plane of array irradiance #2 uint16 W/m² 0 Empty 65535
91 1 Diffuse irradiance #2 uint16 W/m² 0 65535 65535
92 1 Direct irradiance #2 uint16 W/m² 0 65535 65535
93 1 Rear side plane of array irradiance #2 uint16 W/m² 0 Empty 65535
94 1 Global horizontal irradiance uint16 W/m² 0 65535 65535
95 1 Plane of array irradiance #3 uint16 W/m² 0 65535 65535
96 1 Diffuse irradiance #3 uint16 W/m² 0 65535 65535
97 1 Direct irradiance #3 uint16 W/m² 0 65535 65535
98 1 Rear side plane of array irradiance #3 uint16 W/m² 0 Empty 65535
99 1 Sunspec BOM temperature model identifier uint16 n/a n/a 303 Empty
100 1 Back of module temperature model length uint16 n/a n/a 3 Empty
101 1 Back of module temperature #1 int16 °C −1 Empty −32768
102 1 Back of module temperature #2 int16 °C −1 Empty −32768
103 1 Back of module temperature #3 int16 °C −1 Empty −32768
104 1 Back of module temperature #4 int16 °C −1 Empty −32768
105 1 Sunspec inclinometer model identifier uint16 n/a n/a 304 Empty
106 1 Inclinometer model length uint16 n/a n/a 48 Empty
107 2 Inclination X #1 int32 deg −2 Empty −2147483648
109 2 Inclination Y #1 int32 deg −2 Empty −2147483648
111 2 Inclination Z #1 int32 deg −2 −2147483648 −2147483648
113 2 Inclination X #2 int32 deg −2 Empty −2147483648
115 2 Inclination Y #2 int32 deg −2 Empty −2147483648
117 2 Inclination Z #2 int32 deg −2 −2147483648 −2147483648
119 2 Inclination X #3 int32 deg −2 Empty −2147483648
121 2 Inclination Y #3 int32 deg −2 Empty −2147483648
123 2 Inclination Z #3 int32 deg −2 −2147483648 −2147483648
125 2 Inclination X #4 int32 deg −2 Empty −2147483648
127 2 Inclination Y #4 int32 deg −2 Empty −2147483648
129 2 Inclination Z #4 int32 deg −2 −2147483648 −2147483648
131 2 Inclination X #5 int32 deg −2 Empty −2147483648
133 2 Inclination Y #5 int32 deg −2 Empty −2147483648
135 2 Inclination Z #5 int32 deg −2 −2147483648 −2147483648
137 2 Inclination X #6 int32 deg −2 Empty −2147483648
139 2 Inclination Y #6 int32 deg −2 Empty −2147483648
141 2 Inclination Z #6 int32 deg −2 −2147483648 −2147483648
143 2 Inclination X #7 int32 deg −2 Empty −2147483648
145 2 Inclination Y #7 int32 deg −2 Empty −2147483648
147 2 Inclination Z #7 int32 deg −2 −2147483648 −2147483648
149 2 Inclination X #8 int32 deg −2 Empty −2147483648
151 2 Inclination Y #8 int32 deg −2 Empty −2147483648
153 2 Inclination Z #8 int32 deg −2 −2147483648 −2147483648
155 1 Vaisala Albedo model identifier uint16 n/a n/a 64900 Empty
156 1 Albedo model length uint16 n/a n/a 3 Empty
157 1 Albedo instant value uint16 n/a −2 Empty 65535
158 1 Albedo 24 h average uint16 n/a −2 Empty 65535
159 1 Global horizontal irradiance reflected #1 uint16 n/a 0 Empty 65535
160 1 Vaisala System status model identifier uint16 n/a n/a 64901 Empty
161 1 System status model length uint16 n/a n/a 3 Empty
162 1 DC supply voltage uint16 V −1 Empty 65535
163 1 Internal temperature int16 °C −1 Empty −32768
164 1 Enclosure door closed uint16 n/a 0 Empty 65535
165 1 Vaisala Soiling model identifier uint16 n/a n/a 64902 Empty
166 1 Soiling model length uint16 n/a n/a 14 Empty
167 1 Soiling ratio 1 uint16 % −1 Empty 65535
168 1 Soiling ratio 1 24 h mean uint16 % −1 Empty 65535
169 1 Soiling ratio 2 uint16 % −1 Empty 65535
170 1 Soiling ratio 2 24 h mean uint16 % −1 Empty 65535
171 1 Transmission loss 1 int16 % −1 Empty −32768
172 1 Transmission loss 1 24 h mean int16 % −1 Empty −32768
173 1 Transmission loss 2 int16 % −1 Empty −32768
174 1 Transmission loss 2 24 h mean int16 % −1 Empty −32768
175 1 Operating voltage uint16 V −3 Empty 65535
176 1 Operating mode uint16 n/a n/a Empty 65535
177 1 Status flags uint16 n/a n/a Empty 65535
178 1 Calibration status berofe uint16 n/a n/a Empty 65535
179 1 Calibration status after uint16 n/a n/a Empty 65535
180 1 SunSpec end of model identifier uint16 n/a n/a 65535 Empty
181 1 SunSpec end of model length uint16 n/a n/a 0 Empty