Replacing circuit breakers - AWS810-SOLAR

AWS810 Solar Edition Configuration and Maintenance Guide

Document code
M212906EN
Revision
B
Language
English
Product
AWS810-SOLAR
Document type
User guide
  • Flat head screwdriver
  • Crosshead screwdriver

The station may have the following circuit breakers:

  • 10 A for external DC

If the external DC circuit breaker is broken, the station only works on battery power.

  1. Switch off AC (mains) or external DC power, depending on the powering. Make sure that there is no power available to the station.
  2. Disconnect cabling from the circuit breaker.
  3. Release the DIN rail locking piece and remove the circuit breaker from the DIN rail.
  4. Insert the new circuit breaker on the DIN rail and snap it to place.
  5. Connect the cabling to the new circuit breaker.
  6. Switch on power.