  • Side cutters
A few pieces of termination resistors are included in the weather station delivery.
  1. Bend the other end of the resistor wire as shown in the following figure.
  2. Cut the other end of the wire to the same length.
  3. Insert the resistor ends in the spring‑cage connector, between pins 2 and 3 (or 6 and 7), in ports 1–3 of Serial Module DMS801. It does not matter which end goes to which pin.
    If both pin pairs 2 and 3, and 6 and 7 are already used for sensor wiring, add external splicing connector to add the resistor.