Configuring quality control limits for DustIQ - AWS810-SOLAR

AWS810 Solar Edition Configuration and Maintenance Guide

Document code
M212906EN
Revision
B
Language
English
Product
AWS810-SOLAR
Document type
User guide

You can configure the precipitation and condensation thresholds as well as range check limits.

  1. In the Web UI, go to Settings > Station parameters.
  2. Under parameter group kz_dustiq_qc, set the precipitation and condensation thresholds.
    If you set checkCondensation and checkPrecipitation to false, precipitation and condensation are ignored in quality control and observations made under precipitation and condensation are not rejected.
  3. Under parameter group qc, set the range check limits.
    The configurable parameters for the range check limits are:
    Table 1. DustIQ range check limit parameters
    Parameter Description
    TRLOSS_hi Transmission loss high limit
    TRLOSS_lo Transmission loss low limit
    SRS_hi Soiling ratio high limit
    SRS_lo Soiling ratio low limit
    U_hi Sensor power supply voltage high limit
    U_lo Sensor power supply voltage low limit
    The quality range check limits are configured per sensor type (not per sensor).
  4. To save the changes and take them into use, select Save and restart script.