Quality control procedure for DustIQ observations - AWS810-SOLAR

AWS810 Solar Edition Configuration and Maintenance Guide

Document code
M212906EN
Revision
B
Language
English
Product
AWS810-SOLAR
Document type
User guide
The quality of DustIQ soiling sensor readings (observations and device status information) is affected by several factors. If the quality of the sensor reading is not within the set limits, the sensor reading data does not pass the quality control and the data is rejected.
Table 1. Reasons for rejected quality of DustIQ sensor reading
Reason Description Value
Sensor status Sensor not in the normal operating mode. QUAL_INSTRUMENT_ERROR or QUAL_ACCEPTED_SUSPICIOUS
Range check Performed for transmission loss and soiling ratio observations, device tilt, and operating voltage. If the values are not inside the accepted range, the quality is rejected. QUAL_REJECTED
Precipitation Observations made under precipitation. QUAL_REJECTED
Condensation Observations made under condensation. QUAL_REJECTED