BMU801 specifications - AWS810-SOLAR

AWS810 Solar Edition System Description

Document code
M212902EN
Revision
D
Language
English
Product
AWS810-SOLAR
Document type
Technical description

The specifications described in this section are valid for BMU801 devices with serial number W2440101 onwards. The serial number is printed on a sticker on the back of BMU801.

For specifications of older BMU801 devices (serial number W2440100 and earlier), see revision A of BMU801 User Guide (M212710EN).

BMU801 operating environment
Property Description/Value

Operating environment

Outdoor use 1

Use in wet location

Yes 1

Operating temperature

−40 … +70 °C (−40 …+158 °F) 2 3

Storage temperature

−60 … +85 °C (−76 … +185 °F)

Operating humidity

0–100 %RH, non‑condensing

Pollution degree

2

Maximum operating altitude

3000 m (approx. 9800 ft)

IP rating

IP20: Protected against solid foreign objects of 12.5 mm Ø and greater.

BMU801 inputs and outputs
Property Description/Value
Compatible battery types Valve‑regulated lead‑acid (VRLA) battery
Input voltage (all DC inputs) 9–28 V DC 4 5
Input voltage (for 12 V VRLA battery charging) 15–28 V DC
Overvoltage category I
Maximum input current 10 A
Charging voltage (for 12 V VRLA battery charging) 12–15.6 V
Maximum battery charging current 6 A
Nominal output voltage 24 V 6
Maximum continuous output (load) current 10 A
Nominal voltage, solar panel 12 V DC
Maximum power, solar panel 100 W
NTC connectors 2 × push-in connector for NTC temperature sensors
Mating connectors
2 × battery, 2 × solar panel, power in/out Phoenix Contact FKCN 2,5/2‑ST‑5,08
Modbus M8 4‑pin female
GPIO

Phoenix Contact DFMC 1,5/3‑ST‑3,5‑LR

  • 2 × status output (max. 100 mA / 30 V)
  • 1 × battery voltage output
  • 1 × force-off input
BMU801 compliance
Test Applied standard Description/Value

EU directives and regulations

EMC Directive (2014/30/EU)

Low Voltage Directive (2014/35/EU)

RoHS Directive (2011/65/EU) as amended by 2015/863

EMC immunity

EN 61326‑1, industrial environment

EMC emissions

CISPR 32 / EN 55032, Class B

Electrical safety

IEC/EN/UL/CSA‑C22.2 61010‑1

Compliance marks

CE, RCM, UKCA
Listing marks MET Recognition (USA and Canada)
Test Applied standard Description/Values

Vibration (sinusoidal)

IEC 60068‑2‑6

IEC 60945

5–13.2 Hz, 1 mm (0.04 in) amplitude

13.2–200 Hz, 0.7 g

Shock

IEC 60068‑2‑27

15 g, 11 ms, saw-tooth

30 g, 11 ms, half-sine

Dry heat

IEC 60068‑2‑2

+70 °C (+158 °F)

Damp heat

IEC 60068‑2‑78

+40 °C (+104 °F), 95 %RH

Cold

IEC 60068‑2‑1

−60 °C (−76 °F)

BMU801 mechanical specifications
Property Description/Value
Dimensions (H × W × D) 120 × 33 × 84 mm (4.72 × 1.30 × 3.31 in)
Weight 0.22 kg (0.49 lb)
Mounting DIN rail 35 mm (1.4 in)
Materials
Screws, washers Stainless steel AISI 316
DIN rail locking piece Stainless steel AISI 630
Frame profile Aluminum EN AW-6060 T6
End covers Plastic PC/ABS
1 Inside a weather-proof enclosure (IP65).
2 Recommended operating temperature for batteries may be different. See manufacturer documentation.
3 When the battery or its ambient temperature exceeds the operating temperature limit of the battery, BMU801 stops charging but the capability to supply power to the weather station (or other system) remains.
4 The short-term maximum voltage is 30 V DC.
5 When using external DC power supply, install an external 10 A or 16 A disconnection device, such as slow-blow fuse, for the DC input.
6 The actual output equals the DC input voltage when DC power supply or solar panel is connected. If no DC power or solar power is available, the output equals the battery voltage.