AWS810 Solar Edition system specifications - AWS810-SOLAR

AWS810 Solar Edition System Description

Document code
M212902EN
Revision
D
Language
English
Product
AWS810-SOLAR
Document type
Technical description
AWS810 Solar Edition operating environment
Property Description/Value

Operating environment

Outdoor use

Use in wet location

Yes

Operating temperature with 28 Ah backup battery or without battery 1

−40 … +60 °C (−40 … +140 °F)

Operating temperature with 24 Ah backup battery 1

−40 … +50 °C (−40 … +122 °F)

Storage temperature 2 −60 ... +70 °C (−76 ... +158 °F)

Operating humidity

0–100 %RH

Pollution degree

2

Maximum operating altitude

3000 m (approx. 9800 ft)

AWS810 Solar Edition powering specifications
Property Description/Value
AC (mains) power

100–240 V AC, −15 % … +10 %

50–60 Hz

6.8 A maximum (100 V AC)

Mains fuse (nominal) 10 A
External DC

15–28 V DC

10 A maximum

Solar panel

70 W, typical

15–28 V DC

6 A maximum (each), 10 A combined (both inputs)

Internal backup battery 12 V / 24–28 Ah (48–56 Ah with 2 batteries)
Overvoltage category II
AWS810 standard communication options
Property Description/Value
Wireless communication LTE Cat 4 cellular modem (with UMTS/HSPA+ and GSM/GPRS/EDGE support)
Landline communication RS‑232, RS‑485, LAN
Ethernet communication HTTPS, TCP socket, SFTP, FTP
Data collection software Vaisala cloud service (Xweather Insight)
Communication protocols

Modbus TCP (SunSpec)

ASCII (SMSAWS)

Local maintenance connection USB-C, browser-based Web UI

For other data validation, calculation, report, mast, powering, sensor, communication data collection software options, and measurement unit conversions, contact Vaisala.

AWS810 compliance
Property Description/Value

EU directives and regulations

EMC Directive (2014/30/EU)

Low Voltage Directive (2014/35/EU)

RoHS Directive (2011/65/EU) as amended by 2015/863

EMC immunity

EN 61326‑1, industrial environment 34

FCC part 15 B, Class B

ICES‑3 / NMB‑3 (Class B)

EMC emissions

CISPR 32 / EN 55032, Class B 5

Electrical safety

IEC/EN/AS/UL/CSA‑C22.2 61010‑1

Eye safety (SFP modules)

Class 1 laser product, EN 60825‑1:2014

Compliance marks

CE, FCC, RCM, UKCA
AWS810 environmental compliance
Test Applied standard or test procedure Specification
Operation
Cold IEC 60068-2-1 −40 °C (−40 °F)
Dry heat IEC 60068-2-2 +60 °C (+140 °F)
Damp heat IEC 60068-2-78 +40 °C (+104 °F), 93 %RH
Vibration (sinusoidal) IEC 60068-2-6

Frequency range 5–200 Hz

1.2 mm/s velocity, 5–12 Hz

0.7 g, 12–200 Hz

Shock IEC 60068-2-27 5.0 g, pulse duration 11 ms with 100 pulses in each direction
Vibration (random) IEC 60068-2-64 5–100 Hz
Storage
Cold 6 IEC 60068-2-1 −60 °C (−76 °F)
Dry heat 6 IEC 60068-2-2 +70 °C (+158 °F)
Transport
Vibration (random) IEC 60068-2-64 5–200 Hz
Shock IEC 60068-2-27 18 g, pulse duration 6 ms with 100 pulses in each direction
Rough handling IEC 600068-2-31 Drop height 25 cm (9.84 in)
AWS810 electromagnetic compatibility
Test Applied standard or test procedure Specification
Emissions radiated

CISPR 32 / EN 55032, Class B

30 MHz–6 GHz
Emissions conducted to mains (AC)

CISPR 32 / EN 55032, Class B

150 kHz–30 MHz

Emissions conducted to telecommunication lines

CISPR 32 / EN 55032, Class B

150 kHz–30 MHz
Emissions radiated, Class B

FCC part 15 B, Class B

30 MHz–18 GHz
Emissions conducted, Class B

FCC part 15 B, Class B

150 kHz–30 MHz
Emissions, harmonic current EN 61000-3-2 0–40th harmonic
Immunity to electrostatic discharge EN 61000-4-2

Contact, HCP ±4 kV

Contact, VCP ±4 kV

Contact discharge, all conductive parts ±4 kV

All discharge, all nonconductive parts ±2 kV, ±4 kV, ±8 kV

Immunity to RF field (80 MHz ... 6 GHz) EN 61000-4-3

10 V/m (80 MHz–1 GHz)

3 V/m (1–6 GHz)

Immunity to electric fast transient EN 61000-4-4

±2 kV AC, ±1 kV I/O

Immunity to surge EN 61000-4-5

Line to line ±1 kV (AC and I/O)

Line to ground ±2 kV (AC and I/O)

Immunity to conducted RF EN 61000-4-6

3 V r.m.s. (150 kHz–80 MHz)

Immunity to voltage dips and short interrupts IEC 61000-4-11

0 % 1 cycle

40 % 10 cycles

70 % 25 cycles

0 % 250 cycles

1 Excluding ARG314. See the manufacturer documentation.
2 Excluding backup battery. See the manufacturer documentation.
3 Excluding EKO MS series and Kipp & Zonen SMP12 pyranometers.
4 Modem Carrier Module DMX801 complies with EN 61326‑1 basic level. Ethernet connection requires external surge protection to comply with EN 61326‑1 industrial environment level.
5 Class A, if Ethernet Switch Module DME801 includes SFP modules.