Property | Description/Value |
---|---|
Operating environment |
Outdoor use |
Use in wet location |
Yes |
Operating temperature with 28 Ah backup battery or without battery 1 |
−40 … +60 °C (−40 … +140 °F) |
Operating temperature with 24 Ah backup battery 1 |
−40 … +50 °C (−40 … +122 °F) |
Storage temperature 2 | −60 ... +70 °C (−76 ... +158 °F) |
Operating humidity |
0–100 %RH |
Pollution degree |
2 |
Maximum operating altitude |
3000 m (approx. 9800 ft) |
Property | Description/Value |
---|---|
AC (mains) power |
100–240 V AC, −15 % … +10 % 50–60 Hz 6.8 A maximum (100 V AC) |
Mains fuse (nominal) | 10 A |
External DC |
15–28 V DC 10 A maximum |
Solar panel |
70 W, typical 15–28 V DC 6 A maximum (each), 10 A combined (both inputs) |
Internal backup battery | 12 V / 24–28 Ah (48–56 Ah with 2 batteries) |
Overvoltage category | II |
Property | Description/Value |
---|---|
Wireless communication | LTE Cat 4 cellular modem (with UMTS/HSPA+ and GSM/GPRS/EDGE support) |
Landline communication | RS‑232, RS‑485, LAN |
Ethernet communication | HTTPS, TCP socket, SFTP, FTP |
Data collection software | Vaisala cloud service (Xweather Insight) |
Communication protocols |
Modbus TCP (SunSpec) ASCII (SMSAWS) |
Local maintenance connection | USB-C, browser-based Web UI |
For other data validation, calculation, report, mast, powering, sensor, communication data collection software options, and measurement unit conversions, contact Vaisala. |
Property | Description/Value |
---|---|
EU directives and regulations |
EMC Directive (2014/30/EU) Low Voltage Directive (2014/35/EU) RoHS Directive (2011/65/EU) as amended by 2015/863 |
EMC immunity |
EN 61326‑1, industrial environment 34 FCC part 15 B, Class B ICES‑3 / NMB‑3 (Class B) |
EMC emissions |
CISPR 32 / EN 55032, Class B 5 |
Electrical safety |
IEC/EN/AS/UL/CSA‑C22.2 61010‑1 |
Eye safety (SFP modules) |
Class 1 laser product, EN 60825‑1:2014 |
Compliance marks |
CE, FCC, RCM, UKCA |
Test | Applied standard or test procedure | Specification |
---|---|---|
Operation | ||
Cold | IEC 60068-2-1 | −40 °C (−40 °F) |
Dry heat | IEC 60068-2-2 | +60 °C (+140 °F) |
Damp heat | IEC 60068-2-78 | +40 °C (+104 °F), 93 %RH |
Vibration (sinusoidal) | IEC 60068-2-6 |
Frequency range 5–200 Hz 1.2 mm/s velocity, 5–12 Hz 0.7 g, 12–200 Hz |
Shock | IEC 60068-2-27 | 5.0 g, pulse duration 11 ms with 100 pulses in each direction |
Vibration (random) | IEC 60068-2-64 | 5–100 Hz |
Storage | ||
Cold 6 | IEC 60068-2-1 | −60 °C (−76 °F) |
Dry heat 6 | IEC 60068-2-2 | +70 °C (+158 °F) |
Transport | ||
Vibration (random) | IEC 60068-2-64 | 5–200 Hz |
Shock | IEC 60068-2-27 | 18 g, pulse duration 6 ms with 100 pulses in each direction |
Rough handling | IEC 600068-2-31 | Drop height 25 cm (9.84 in) |
Test | Applied standard or test procedure | Specification |
---|---|---|
Emissions radiated |
CISPR 32 / EN 55032, Class B |
30 MHz–6 GHz |
Emissions conducted to mains (AC) |
CISPR 32 / EN 55032, Class B |
150 kHz–30 MHz |
Emissions conducted to telecommunication lines |
CISPR 32 / EN 55032, Class B |
150 kHz–30 MHz |
Emissions radiated, Class B |
FCC part 15 B, Class B |
30 MHz–18 GHz |
Emissions conducted, Class B |
FCC part 15 B, Class B |
150 kHz–30 MHz |
Emissions, harmonic current | EN 61000-3-2 | 0–40th harmonic |
Immunity to electrostatic discharge | EN 61000-4-2 |
Contact, HCP ±4 kV Contact, VCP ±4 kV Contact discharge, all conductive parts ±4 kV All discharge, all nonconductive parts ±2 kV, ±4 kV, ±8 kV |
Immunity to RF field (80 MHz ... 6 GHz) | EN 61000-4-3 |
10 V/m (80 MHz–1 GHz) 3 V/m (1–6 GHz) |
Immunity to electric fast transient | EN 61000-4-4 |
±2 kV AC, ±1 kV I/O |
Immunity to surge | EN 61000-4-5 |
Line to line ±1 kV (AC and I/O) Line to ground ±2 kV (AC and I/O) |
Immunity to conducted RF | EN 61000-4-6 |
3 V r.m.s. (150 kHz–80 MHz) |
Immunity to voltage dips and short interrupts | IEC 61000-4-11 |
0 % 1 cycle 40 % 10 cycles 70 % 25 cycles 0 % 250 cycles |