WXT536 specifications - AWS810-SOLAR

AWS810 Solar Edition System Description

Document code
M212902EN
Revision
D
Language
English
Product
AWS810-SOLAR
Document type
Technical description
WXT530 barometric pressure measurement performance
Property Description/Value
Observation range 500–1100 hPa
Accuracy (for sensor element) at 600–1100 hPa

±0.5 hPa at 0 … +30 °C (+32 … +86 °F)

±1 hPa at −52 … +60 °C (−60 … +140 °F)

Output resolution 0.1 hPa / 10 Pa / 0.001 bar / 0.1 mmHg / 0.01 inHg
Units available hPa, Pa, bar, mmHg, inHg
WXT530 air temperature measurement performance
Property Description/Value
Observation range −52 … +60 °C (−60 … +140 °F)
Accuracy (for sensor element) at +20 °C (+68 °F) 1 ±0.3 °C (±0.54 °F)
Output resolution 0.1 °C (0.1 °F)
Units available °C, °F
WXT530 relative humidity measurement performance
Property Description/Value
Observation range 0–100 %RH
Accuracy (for sensor element) 2

±3 %RH at 0–90 %RH

±5 %RH at 90–100 %RH

Output resolution 0.1 %RH
PTU measuring interval 1–3600 s (= 60 min), at 1 s steps
WXT530 precipitation measurement performance
Property 3 Description/Value
Collecting area 60 cm2 (9.3 in2)
Rainfall 4
Output resolution 0.01 mm (0.001 in)
Field accuracy for daily accumulation 5 Better than 5 %, weather-dependent
Units available mm, in
Duration Counting each 10‑second increment whenever droplet detected
Duration output resolution 10 s
Intensity Running 1‑minute average, 10 s steps
Intensity observation range 0–200 mm/h (0–7.87 in/h) (broader with reduced accuracy)
Intensity output resolution 0.1 mm/h (0.01 in/h)
Units available mm/h, in/h
Hail 6
Output resolution 0.1 hits/cm2 (1 hits/in2), 1 hit
Units available hits/cm2, hits/in2, hits

Intensity output resolution

0.1 hits/cm2h (1 hits/in2h), 1 hit/h
Units available hits/cm2h, hits/in2h, hits/h
WXT530 wind measurement performance
Property Description/Value
Wind speed 7
Observation range 0–60 m/s (134 mph)
Reporting range 0–75  m/s (168 mph)
Response time 0.25 s
Available variables Average, maximum, and minimum
Accuracy ±3 % at 10 m/s (22 mph)
Output resolution 0.1 m/s (km/h, mph, knots)
Units available m/s, km/h, mph, knots
Wind direction 7
Azimuth 0–360°
Response time 0.25 s
Available variables Average, maximum, and minimum
Accuracy ±3.0° at 10 m/s (22 mph)
Output resolution
Averaging time 1–3600 s, sample rate 1, 2, or 4 Hz (configurable)
WXT530 operating environment
Property Description/Value

Operating environment

Outdoor use

Operating temperature

−52 … +60 °C (−60 … +140 °F)

Storage temperature

−60 … +70 °C (−76 … +158 °F)

Operating humidity

0–100 %RH

Operating pressure

500–1100 hPa
Wind 8 0–60 m/s (0–134 mph)

IP rating

Without mounting kit: IP65: Dust-tight. Protected from water jets from any direction.

With mounting kit: IP66: Dust-tight. Protected from powerful water jets from any direction.

WXT530 compliance
Property Description/Value

EU directives and regulations

EMC Directive (2014/30/EU)

RoHS Directive (2011/65/EU) as amended by 2015/863

Electromagnetic compatibility (EMC)

EN 61326‑1, industrial environment

CISPR 32 / EN 55032, Class B

Environmental

IEC 60068‑2‑1, 2, 6, 14, 30, 31, 78

IEC 60529, VDA 621‑415

Maritime

IEC 60945 (Exposed)

DNV GL Type Examination Certificate No. TAA00000VF

Compliance marks

CE, RCM, RoHS, China RoHS, UKCA
WXT530 mechanical specifications
Property Description/Value
Weight

WXT536

0.7 kg (1.54 lb)
Materials
Radiation shield, top, and bottom parts Polycarbonate +20 % fiberglass
Precipitation sensor plate Stainless steel (AISI 316)
WXT536 dimensions
WXT530 mounting kit (212792) dimensions
1
Mounting kit with adapter sleeve for Ø 26.7 mm (1.05 in) mast tube
2
Mounting kit without adapter sleeve for Ø 30 mm (1.18 in) mast tube
SENSORARMFIX60 dimensions
1 A naturally aspirated radiation shield is applied which can affect readings in calm wind.
2 A naturally aspirated radiation shield is applied which can affect readings in calm wind.
3 Precipitation measurement is performed for liquid precipitation.
4 Cumulative accumulation after the latest automatic or manual reset.
5 Due to the nature of the phenomenon, deviations caused by spatial variations may exist in precipitation readings, especially in short time scale. The accuracy specification does not include possible wind-induced error.
6 Cumulative number of hits against collecting surface.
7 NTP (normal temperature and pressure) condition applied for wind tunnel testing.
8 Due to the measurement frequency used in the sonic transducers, RF interference in the 200–400 kHz range can disturb wind measurement.