DMU801 specifications - AWS810-SOLAR

AWS810 Solar Edition System Description

Document code
M212902EN
Revision
D
Language
English
Product
AWS810-SOLAR
Document type
Technical description
DMU801 operating environment
Property Description/Value
Operating temperature 1

−40 … +85 °C (−40 … +185 °F)

Extended operating temperature (available on request)

−60 … +85 °C (−76 … +185 °F)

Storage temperature

−60 … +85 °C (−76 … +185 °F)

Operating humidity

0–100 %RH, non‑condensing

DMU801 powering specifications
Property Description/Value
Operating voltage 8–32 V DC (maximum 10 A)
Power consumption, typical 500 mW
Heating voltage 24 V DC nominal
Maximum input current for heating 12 A
Mating connectors (power/heating input) 2 × Phoenix Contact FKCN 2,5/2‑ST‑5,08 (included)
DMU801 processing system
Property Description/Value
Processor ARM Cortex A9, 800 MHz
Memory 1 GB DDR3L RAM, 8 GB eMMC Flash
External memory SD card up to 32 GB 2
Operating system Linux
Communications protocol IPv4 and IPv6
Real-time clock (standard)
Accuracy Better than 20 s/month
Backup battery CR1225/BR1225
Backup time Minimum 5 years
DMU801 compliance
Property Description/Value

EU directives and regulations

EMC Directive (2014/30/EU)

RoHS Directive (2011/65/EU) as amended by 2015/863

EMC immunity

EN 61326‑1, industrial environment 3

EMC emissions

CISPR 32 / EN 55032, Class B 4

FCC part 15 B, Class B

ICES‑3 / NMB‑3 (Class B)

Compliance marks

CE, FCC, ICES, RCM, UKCA
Test Applied standard Description/Value
Maritime IEC 60945

Vibration (sinusoidal)

IEC 60068‑2‑6

5–13.2 Hz, 1 mm (0.04 in) amplitude

13.2–200 Hz, 0.7 g

Rough handling

IEC 60068‑2‑31

Drop height 100 cm (39.37 in)

Shock

IEC 60068‑2‑27

15 g, 11 ms, saw‑tooth

Dry heat

IEC 60068‑2‑2

+85 °C (+185 °F)

Damp heat

IEC 60068‑2‑78

+40 °C (+104 °F), 95 %RH

Cold

IEC 60068‑2‑1

−60 °C (−76 °F)
DMU801 inputs and outputs
Property Description/Value
Ethernet
Ports eth0 on CPU, additional ports with plug‑in modules
Supported standard IEEE 802.3u
Physical layer Base‑T
Data rate 10/100 Mbps
Connectors RJ45 with link LEDs
Data transmission Full/Half‑duplex with auto‑negotiation
USB
Ports 1
Supported standard USB 2.0
Signaling High speed
Connectors USB‑C
Serial
Ports
  • 1 × RS‑232 / RS‑485 / SDI‑12 port
  • 2 × RS‑485 ports
  • Additional ports with plug‑in modules
Supported bit rate 1200–115 200 bps
Power output 5 × software controllable power output pins
Signals
  • RS‑232: RXD, TXD
  • RS‑485: D+/D−
Digital I/O 4 × 3.3 V logic level GPIO pins, pulse count capable
Mating connectors
  • 2 × Phoenix Contact DFMC 1,5/4‑ST‑3,5‑LR (included)
  • 1 × M8 4‑pin male
Note: 4‑wire RS‑485/RS‑422 is supported by using 2 × 2‑wire RS‑485.
TCP/IP
Supported protocols DHCP, DNS, NTP, ARP, ICMP Echo, TCP/IP, SSH, UDP, DTLS, HTTPS 5
DMU801 mechanical specifications
Property Description/Value
Weight

8‑slot unit: 0.71 kg (1.57 lb)

Mounting DIN rail 35 mm (1.4 in)
Dimensions (H × W × D) 6
2 slots

120 × 77 × 84 mm (4.72 × 3.03 × 3.31 in)

8 slots

120 × 185 × 84 mm (4.72 × 7.28 × 3.31 in)

Materials
Screws, washers Stainless steel AISI 316
DIN rail locking piece Stainless steel AISI 630
Frame profile Aluminum EN AW‑6060 T6
End covers Plastic PC/ABS
1 Operating temperature of some of the DMU801 plug‑in modules may be different. See the plug‑in module datasheets.
2 SD card available as accessory.
3 Modem Carrier Module DMX801 complies with EN 61326‑1 basic level. Ethernet connection requires external surge protection to comply with EN 61326‑1 industrial environment level.
4 Class A, if Ethernet Switch Module DME801 includes SFP modules.
5 The list is subject to change.
6 Reserve some extra space for connectors and cables. For example, sensor connectors require a minimum of 20 mm (0.8 in) additional space from the DMU801 frame.