Slew rate limit - PR53 - PR53AC - PR53AP - PR53GC - PR53GP - PR53M - PR53SD - PR53W

PR53 Series User Guide

Document code
M212898EN
Revision
F
ft:locale
en-US
Product
PR53
PR53AC
PR53AP
PR53GC
PR53GP
PR53M
PR53SD
PR53W
Document type
User guide

If the process signal has short erroneous high or low peaks, the slew rate limiting can be used to cut their effects.

The slew rate damping limits the maximum change for the output signal in 1 s. The slew rate limit damping is recommended for random noise suppression as it is non-linear.

Select Slew rate to set the slew rate limit. Typical values depend on the concentration unit but are typically 0.05 % to 1 % when the concentration is measured in %.

The following figure gives an example of different slew rate limits.Slew rate damping
To avoid overdamping, do not make the signal insensitive.