Activating and pairing device control modules - DA10

DA10 Installation Guide

Document code
M212894EN
Revision
C
Language
English
Product
DA10
Document type
User guide
  • Device activation code sticker (2 pcs, 1 for each device control module)
  • USB-C cable or Ethernet cable

After you have activated DMU801-DA10, activate the device control modules and pair them with each other and with DMU801-DA10.

  1. Connect your laptop to the USB port of DMU801-DA10.
    1
    USB port
  2. Open a web browser and go to the DMU801-DA10 Web UI address:

    https://192.168.10.2/devices

  3. Select Devices.
  4. Select Add device.
  5. Type the IP address of the device control module and select Add device.

    The IP addresses of the device control modules are:

    • 192.168.2.104
    • 192.168.2.105
  6. Select the device you added.
  7. Select Pair device.
  8. Type the activation code and select Pair.
  9. Repeat this for the other device control module.
  10. To pair the device control modules with DMU801-DA10, select Add device, type the IP address of the DMU801-DA10, and select Add device.

    The IP address of DMU801-DA10 is:

    • 192.168.2.110
  11. Select Vaisala DMU801-<serial number> and Pair device.

    Provide the admin username and password you created when activating DMU801-DA10.

  12. If the message Configuration update needed appears next to the any of the devices, select Update.