Installing DA10 - DA10

DA10 Installation Guide

Document code
M212894EN
Revision
B
Language
English
Product
DA10
Document type
User guide
  • Spirit level
  • Wrench
Figure 1. Weight of main units and lifting handles and locations
1
Lifting locations
2
Lifting handles

DA10 is delivered with its main cabling connected inside the radiation shield.

WARNING For eye safety reasons, DA10 must be installed vertically.
  1. Lift the radiation shield on the foundation screws.

    Use a spirit level to check that the instrument pedestal is leveled horizontally.

    WARNING When the measurement units are in place do not use the lifting hooks for lifting the instrument. The lifting hooks cannot support the full weight of the instrument. The lifting hooks are for lifting the radiation shield when empty.
    1
    Lifting hooks (2 pcs)
  2. Attach the washers and nuts and tighten the nuts.

    Open the back door and remove the bottom cover to make placing the washers and tightening the nuts easier.

    1
    Hex nut M10 DIN934 A4 (4 pcs)
    2
    Flat washer M10 DIN125 A4 (4 pcs)
    3
    Foundation screw (4 pcs)
    4
    Instrument pedestal
    5
    Foundation

    There are 4 extra nuts and washers in the accessories package. They are not needed during installation.

  3. Mount the far-range measurement unit inside the radiation shield.