1. Select the installation height. The recommended installation height is 2–5 m (6 ft–16 ft). Low installation height is more representative of the temperature and relative humidity near the road surface. |
For the surface temperature measurement, select the installation height so that you can aim the sensor at the desired measurement point (max. tilt angle 60°).
|
|
2. Fasten the mounting bracket. Cut off excess steel band or place it neatly into the bracket. |
If you are installing TempCast on diagonal or horizontal structures, use the TempCast mounting adapter. See the separate Installation Note for the instructions. |
3. Use the locking key to lift and secure the device to the bracket. Remove the locking key. |
| For the mounting adapter instructions, see TempCast Mounting Adapter Installation Note (M212913EN) at docs.vaisala.com. |