The status register (0xE000) can report that
one of the following notification types is present:
- 0
- No issues
- 1
- Info
- 2
- Warning
- 3
- Error
Additional details about the status reported in the register 0xE000 can be provided in the 16-bit register 0xE001, as described in the following table.
Bit in E001hex | Meaning | Notes |
---|---|---|
0 (0x0000) | No errors | |
2 (0x0002) | Probe error | Connect to Insight PC software and review the error information in the Diagnostics menu. Check display messages. |
4 (0x0004) | Low supply voltage | The supply voltage is not within the specified range (15–30 V DC (24 V AC ±10 % 50/60 Hz) |
16 (0x0010) | No measurement probe | Probe not connected or Indigo cannot detect the probe. |
32 (0x0020) | Probe warning | Connect to Insight PC software and review the error information in the Diagnostics menu. Check display messages. |