Display messages - INDIGO202 - INDIGO200SERIES

Indigo202 User Guide

Document code
M212843EN
Revision
C
ft:locale
en-US
Product
INDIGO200SERIES
INDIGO202
Content type
Product description
Product description > Features
Product description > Functions
Document type
User guide

The following table lists the display messages that the transmitter uses to inform you about its state.

In addition to the transmitter's messages, the connected probes have probe-specific messages that are also shown on the transmitter display. Messages from the connected probe start with Probe:. For more information on the probe-specific messages, see the probe's documentation.

Indigo transmitter messages shown on display
Display message Description Recommended action
Errors
Supply voltage out of range. The supply voltage is below the minimum (range: 15–30 V DC or 24 V AC ±10 % 50/60 Hz). The error clears when the supply voltage returns to the specified range. Check your power supply and restart the transmitter if needed.
Warnings
No probe connected. The measurement probe is not connected, or the probe is connected poorly and cannot be recognized by the transmitter. Check that you have fastened the probe correctly with the locking wheel.
Unable to measure all parameters. Some of the measurements you have configured to be displayed are currently not available. This can be caused, for example, by the probe heating feature: parameters that are affected by heating cannot be shown while the heating cycle is ongoing. -
Notifications

Probe connected:

The transmitter displays the name of the connected probe. -
Waiting for measurements. The connected probe is preparing measurements (for example, at start-up or after a probe restart). -
Date and time not set. The transmitter has lost its date and time settings. This can occur, for example, if the transmitter is powered off for a long time.

Connect the transmitter to the Insight PC software for automatic date and time setup.