Ordering devices for fuel cell use - HMP7 - HMT310 - HMT330

HMP7 and HMT317/337 for Fuel Cell Applications Technical Note

Document code
M212840EN
Revision
A
Language
English
Product
HMP7
HMT310
HMT330
Document type
Technical note

HMP7 warmed probe

When ordering the HMP7 probe for your fuel cell application, make sure that you order the warmed probe model. Include the following Vaisala items in your order:

Table 1. Fuel cell items for HMP7 warmed probe
Nr Category Selection Code
3 Sensor type Humicap R2 composite sensor, allows sensor purge 1
4 Filter type Membrane SST filter for fuel cell applications E
5 Sensor purge Fast probe heat on, purge on 7
10 Probe mounting accessory

Swagelok for NPT ½" thread

or

Swagelok for 3/8" thread

G or H
Table 2. Example order code for HMP7 for fuel cell use
1 2 3 4 5 6 7 8 9 10 11
HMPX 7 E 1 E 7 A 0 A 0 G 0

HMT317/337 transmitter with warmed probe

When ordering HMT317 and HMT337 transmitters for your fuel cell application, make sure that you order the transmitter with the warmed probe model. Include the following Vaisala items in your order:

Table 3. Fuel cell items for HMT317 with warmed probe
Nr Category Selection Code
1 Transmitter type Fuel cell model with extended heating F
13 Humidity sensor type Warmed probe without purge, HUMICAP180RC E
14 Sensor protection Membrane SST filter G
16 Installation kit

ISO 3/8 Swagelok connector

or

NPT ½" Swagelok connector

G or H
Table 4. Example order code for HMT317 for fuel cell use
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
HMT310 F C 5 A 1 A A A 1 4 B P E G 1 G 2