BMU801 connectors - AWS310 - AWS310-SITE - AWS810 - AWS810-SOLAR - BMU801

BMU801 User Guide

Document code
M212710EN
Revision
B
Language
English
Product
AWS310
AWS310-SITE
AWS810
AWS810-SOLAR
BMU801
Document type
User guide
BMU801 front and bottom connectors
BMU801 connectors
Number in figure BMU801 connector name Purpose
1 Solar 1 9–28 V DC input from solar panel 1 1
2 Solar 2 9–28 V DC input from solar panel 2 1
3 DC in 9–28 V DC input from DC power supply 1
4 Batt 1 Battery 1 connector
6 NTC Temperature sensing resistor (NTC) connector
5 Batt 2 Battery 2 connector
7 I/O Status output
8 DC out

Power output

Nominal output voltage 24 V 2

9 Modbus Data and control interface
1 For battery charging, the input voltage must exceed the battery voltage (15 V DC or higher for optimal performance).
2 The actual output equals the DC input voltage, when DC power supply or solar panels are connected. If no DC power or solar power is available, the output equals the battery voltage.