New devices are set up but their data is not visible in the Jade service

Wait patiently. When new connections are established it may take up to 30 minutes for the first measurement data to appear in the Jade service. If the data logger has been in power save mode due to lack of an access point connection, there may also be an additional one hour delay. When CWL100 data loggers have a continuous connection, they send their data every 4 minutes.

CWL100 data loggers have a 30 day memory, and you can download measurement data directly from the CWL100 data logger using an USB cable.

See Downloading data using service port.

Location graph is not shown

This means there is not yet enough data available to display the graph. As location graphs display 1 hour averages, enough data points are needed to draw the graph.

Make sure the location is linked to a probe and wait for enough data to be recorded.

LED on the CA10 is red / CA10 is not connecting to network

Red LED on CA10 typically means it does not have an Internet connection, and therefore is not able to connect data loggers to the Jade service. First check that CA10 is connected to the network using an Ethernet cable. If the CA10 is unable to join the network even when physically connected, verify that the network fulfills the connection requirements:

  • The connected network must provide the IP address automatically using DHCP (Dynamic Host Configuration Protocol).
  • CA10 must be able to connect to TCP port 443 (for Jade Smart Cloud service) and UDP port 123 (for Network Time Protocol service) through the firewall.
  • Many corporate networks require connecting devices to be registered before they can connect. In that case, you must provide the MAC address of the access point to your IT administrator. The MAC address is marked on the front of the access point (near the Ethernet connector) and on its type label in the back.

If a suitable fixed network is not available, you can use a cellular modem with an Ethernet connection instead.

CWL100 data logger is displaying one or more error code(s)

Look up the cause and recommended action for the error code in Table 1. Typical causes of error codes include low batteries and the probe becoming disconnected or damaged.