The Ex certification requirements in different regions (for example, ATEX certification in the EU and CML certification in Japan) involve differences in, for example, the specific conditions of use that are applicable to the product in each region. The Ex certification information specific to each region is available in the following chapters:
EU (ATEX), international (IECEx), and US/CAN (MET) Ex certification information
UK (UKEX) Ex certification information
MGP260 series Ex classification by region
Table 1 shows the Ex classifications of MGP260 probes in each MGP260 certification region. For the most up-to-date list of regional certifications, see the MGP261 and MGP262 product pages at www.vaisala.com/MGP261 and www.vaisala.com/MGP262.
Certification region | MGP260 classification |
---|---|
IECEx (international) ATEX (EU) UKEX (UK) |
Ex II 1/2 (1) G Ex eb mb [ia] IIB T3 Ga/Gb -40 °C ≤ Tamb ≤ +60 °C |
USA/Canada (MET) |
NEC 500: Class I, Division 2, Groups C & D; T3 NEC 505: Class I, Zone 0, AEx eb mb [ia] IIB T3 Ga/Gb CSA 60079: Ex eb mb [ia] IIB T3 Ga/Gb |
Japan (CML) | Ex eb mb [ia] IIB T3 Ga/Gb |
Korea (KCs) |
Ex eb mb [ia] IIB T3 Ga/Gb -40 °C ≤ Tamb ≤ +60 °C IECEx EESF 19.0006X 23-KA4BO-0282X |