Regional Ex certification overview - MGP261 - MGP262

MGP260 User Guide

Document code
M212504EN
Revision
C
Language
English
Product
MGP261
MGP262
Document type
User guide

The Ex certification requirements in different regions (for example, ATEX certification in the EU and CML certification in Japan) involve differences in, for example, the specific conditions of use that are applicable to the product in each region. The Ex certification information specific to each region is available in the following chapters:

EU (ATEX), international (IECEx), and US/CAN (MET) Ex certification information

UK (UKEX) Ex certification information

Japan (CML) Ex certification information

Korea (KCs) Ex certification information

MGP260 series Ex classification by region

Table 1 shows the Ex classifications of MGP260 probes in each MGP260 certification region. For the most up-to-date list of regional certifications, see the MGP261 and MGP262 product pages at www.vaisala.com/MGP261 and www.vaisala.com/MGP262.

Table 1. Ex classifications by region
Certification region MGP260 classification

IECEx (international)

ATEX (EU)

UKEX (UK)

Ex II 1/2 (1) G Ex eb mb [ia] IIB T3 Ga/Gb -40 °C ≤ Tamb ≤ +60 °C

USA/Canada (MET)

NEC 500: Class I, Division 2, Groups C & D; T3

NEC 505: Class I, Zone 0, AEx eb mb [ia] IIB T3 Ga/Gb

CSA 60079: Ex eb mb [ia] IIB T3 Ga/Gb

Japan (CML) Ex eb mb [ia] IIB T3 Ga/Gb
Korea (KCs)

Ex eb mb [ia] IIB T3 Ga/Gb -40 °C ≤ Tamb ≤ +60 °C

IECEx EESF 19.0006X