Designing foundation - CL61

CL61 Installation Guide

Document code
M212474EN
Revision
E
Language
English
Product
CL61
Document type
User guide

The standard foundation for the ground installation is a concrete foundation. For the recommended minimum dimensions, see the following figure. Mounting screws and bolts are included in the delivery as well as a setting tool for the wedge bolts.

Figure 1. Foundation construction, view from side
1
Foundation screw M10×160 AISI316 (4 pcs)
2
Wedge bolt M10×40 mm FeZn (4 pcs)
Figure 2. Foundation dimensions and bolt pattern, view from top
Vaisala recommends that the back door of the ceilometer (the side where the measurement unit is) faces north in the northern hemisphere and south in the southern hemisphere. This protects it from midday sun.

You can either use an existing concrete foundation or create a new one.

If CL61 replaces another Vaisala ceilometer using a 4‑bolt mounting system, for example CL51, the existing foundation and foundation screws can be used.