| BWS500 supports all WXT530 series models. |
| Property | Description/Value |
|---|---|
| Observation range | 500 … 1100 hPa |
| Accuracy (for sensor element) at 600 … 1100 hPa |
±0.5 hPa at 0 … +30 °C (+32 … +86 °F) ±1 hPa at −52 … +60 °C (−60 … +140 °F) |
| Output resolution | 0.1 hPa / 10 Pa / 0.001 bar / 0.1 mmHg / 0.01 inHg |
| Units available | hPa, Pa, bar, mmHg, inHg |
| Property | Description/Value |
|---|---|
| Observation range | −52 … +60 °C (−60 … +140 °F) |
| Accuracy (for sensor element) at +20 °C (+68 °F) 1 | ±0.3 °C (±0.54 °F) |
| Output resolution | 0.1 °C (0.1 °F) |
| Units available | °C, °F |
| Property | Description/Value |
|---|---|
| Observation range | 0 … 100 %RH |
| Accuracy (for sensor element) 2 |
±3 %RH at 0 … 90 %RH ±5 %RH at 90 … 100 %RH |
| Output resolution | 0.1 %RH |
| PTU measuring interval | 1 … 3600 s (= 60 min), at 1 s steps |
| Property 3 | Description/Value |
|---|---|
| Collecting area | 60 cm2 (9.3 in2) |
| Rainfall 4 | |
| Output resolution | 0.01 mm (0.001 in) |
| Field accuracy for daily accumulation 5 | Better than 5 %, weather-dependent |
| Units available | mm, in |
| Duration | Counting each 10‑second increment whenever droplet detected |
| Duration output resolution | 10 s |
| Intensity | Running 1‑minute average, 10 s steps |
| Intensity observation range | 0 … 200 mm/h (0 … 7.87 in/h) (broader with reduced accuracy) |
| Intensity output resolution | 0.1 mm/h (0.01 in/h) |
| Units available | mm/h, in/h |
| Hail 6 | |
| Output resolution | 0.1 hits/cm2 (1 hits/in2), 1 hit |
| Units available | hits/cm2, hits/in2, hits |
|
Intensity output resolution |
0.1 hits/cm2h (1 hits/in2h), 1 hit/h |
| Units available | hits/cm2h, hits/in2h, hits/h |
| Property | Description/Value |
|---|---|
| Wind speed 7 | |
| Observation range | 0 … 60 m/s (134 mph) |
| Reporting range | 0 … 75 m/s (168 mph) |
| Response time | 0.25 s |
| Available variables | Average, maximum, and minimum |
| Accuracy | ±3 % at 10 m/s (22 mph) |
| Output resolution | 0.1 m/s (km/h, mph, knots) |
| Units available | m/s, km/h, mph, knots |
| Wind direction 7 | |
| Azimuth | 0 … 360° |
| Response time | 0.25 s |
| Available variables | Average, maximum, and minimum |
| Accuracy | ±3.0° at 10 m/s (22 mph) |
| Output resolution | 1° |
| Averaging time | 1 … 3600 s, sample rate 1, 2, or 4 Hz (configurable) |
| Property | Description/Value |
|---|---|
| Operating voltage | 6 … 24 V DC (−10 … +30 %) |
| Average power consumption |
Minimum: 0.1 mA at 12 V DC (SDI‑12 standby) Typical: 3.5 mA at 12 V DC (typical measuring intervals) 8 Maximum: 15 mA at 6 V DC (constant measurement of all parameters) |
| Heating voltage |
DC, AC, or full-wave rectified AC 12 … 24 V DC (−10 … +30 %) 12 … 17 V ACrms (−10 … +30 %) |
| Typical heating current |
12 V DC: 800 mA, 24 V DC: 400 mA 12 V ACrms: 1.1 A 17 V ACrms: 800 mA |
| Digital outputs | SDI‑12, RS‑232, RS‑485, RS‑422 |
| Communication protocols |
SDI‑12 v1.3, Modbus RTU, ASCII automatic and polled, NMEA 0183 v3.0 with query option |
| Self-diagnostic | Separate supervisor message, unit/status fields to validate measurement stability |
| Startup | Automatic, < 5 seconds from power on to the first valid output |
| Property | Description/Value |
|---|---|
|
Operating environment |
Outdoor use |
|
Operating temperature |
−52 … +60 °C (−60 … +140 °F) |
|
Storage temperature |
−60 … +70 °C (−76 … +158 °F) |
|
Operating humidity |
0 … 100 %RH |
|
Operating pressure |
500 … 1100 hPa |
| Wind 9 | 0 … 60 m/s (0 … 134 mph) |
|
IP rating |
Without mounting kit: IP65: Dust-tight. Protected from water jets from any direction. With mounting kit: IP66: Dust-tight. Protected from powerful water jets from any direction. |
| Property | Description/Value |
|---|---|
|
EU directives and regulations |
EMC Directive (2014/30/EU) RoHS Directive (2011/65/EU) amended by 2015/863 |
|
Electromagnetic compatibility (EMC) |
EN 61326‑1, industrial environment CISPR 32 / EN 55032, Class B |
|
Environmental |
IEC 60068‑2‑1, 2, 6, 14, 30, 31, 78 IEC 60529, VDA 621‑415 |
| Maritime |
IEC 60945 (Exposed) DNV GL Type Examination Certificate No. TAA00000VF |
|
Compliance marks |
CE, RCM, RoHS, China RoHS, UKCA |
| Property | Description/Value |
|---|---|
| Weight | |
|
WXT534, WXT535, WXT536 |
0.7 kg (1.54 lb) |
| WXT531, WXT532, WXT533 | 0.5 kg (1.1 lb) |
| Materials | |
| Radiation shield, top, and bottom parts | Polycarbonate +20 % fiberglass |
| Precipitation sensor plate | Stainless steel (AISI 316) |